{"dataset":{"name":"U.S. Drinking Water Quality — Contaminant Measurements","license":"https://creativecommons.org/licenses/by/4.0/","homepage":"https://www.thewatermap.com"},"meta":{"generatedAt":"2026-07-26T05:35:01.226Z"},"system":{"slug":"ca__corona-city-of__CA3310037","name":"Corona, City of — Corona, Ca","state":"CA","year":2023,"url":"https://www.thewatermap.com/water/ca/corona-corona-ca/2023","apiUrl":"https://www.thewatermap.com/api/water/ca/corona-corona-ca/2023","markdownUrl":"https://www.thewatermap.com/water/ca/corona-corona-ca/2023/llms.txt","coordinates":{"latitude":33.8752945,"longitude":-117.566444},"contaminantsMeasured":24,"contaminantsWithFederalLimit":10,"contaminantsAtOrAboveLimit":2,"contaminantsApproachingLimit":0,"source":{"type":"Consumer Confidence Report (CCR)","description":"Figures are transcribed from the water utility's own annual Consumer Confidence Report, cross-checked by a second model, and approved by a person before publishing."},"families":[{"family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","contaminants":[{"analyteId":"bromate","name":"Bromate","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":"15541-45-4","whatItIs":"A disinfection byproduct formed when bromide-containing water is treated with ozone.","whyItMatters":"Classified as a probable human carcinogen; the EPA sets a strict maximum contaminant level.","measured":{"value":19,"low":0,"high":19,"kind":"range","display":"0–19","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System Wide","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 19"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":19,"low":0,"high":19,"kind":"range","display":"0–19","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System Wide","rawVerbatim":"ND - 19"},{"value":7.9,"low":null,"high":null,"kind":"point","display":"7.9","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System Wide","rawVerbatim":"7.9"}]},{"analyteId":"perchlorate","name":"Perchlorate","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":"14797-73-0","whatItIs":"A chemical used in rocket fuel and fireworks that can also form during disinfection.","whyItMatters":"Can interfere with thyroid hormone production; has no national enforceable limit but is regulated in some states.","measured":{"value":9.4,"low":0,"high":9.4,"kind":"range","display":"0–9.4","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 9.4"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"","average":null,"range":null,"ratio":null},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"","average":null,"range":null,"ratio":null},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"","average":null,"range":null,"ratio":null}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":9.4,"low":0,"high":9.4,"kind":"range","display":"0–9.4","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 9.4"},{"value":2.9,"low":0,"high":2.9,"kind":"range","display":"0–2.9","units":null,"statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 2.9"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":3.3,"low":null,"high":null,"kind":"point","display":"3.3","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"3.3"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]}]},{"family":"inorganic","familyLabel":"Inorganic chemicals","contaminants":[{"analyteId":"bromide","name":"Bromide","family":"inorganic","familyLabel":"Inorganic chemicals","casrn":"24959-67-9","whatItIs":"A naturally occurring salt found in source water.","whyItMatters":"Not directly regulated, but a precursor that increases formation of brominated disinfection byproducts.","measured":{"value":32,"low":0,"high":32,"kind":"range","display":"0–32","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-32"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":32,"low":0,"high":32,"kind":"range","display":"0–32","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-32"},{"value":15.3,"low":null,"high":null,"kind":"point","display":"15.3","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"15.3"}]},{"analyteId":"fluoride","name":"Fluoride","family":"inorganic","familyLabel":"Inorganic chemicals","casrn":"16984-48-8","whatItIs":"A mineral often added to drinking water to help prevent tooth decay.","whyItMatters":"Beneficial at low levels, but long-term exposure above the federal limit can cause bone disease and tooth mottling.","measured":{"value":2,"low":0.26,"high":2,"kind":"range","display":"0.26–2","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"0.26 - 2.0"},"federalStandard":{"type":"MCL","value":4,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0.5},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0.195},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0.1}],"measurements":[{"value":0.9,"low":0.6,"high":0.9,"kind":"range","display":"0.6–0.9","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"0.6 - 0.9"},{"value":0.4,"low":0.3,"high":0.4,"kind":"range","display":"0.3–0.4","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"0.3 - 0.4"},{"value":2,"low":0.26,"high":2,"kind":"range","display":"0.26–2","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"0.26 - 2.0"},{"value":0.78,"low":0,"high":0.78,"kind":"range","display":"0–0.78","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 0.78"},{"value":0.7,"low":null,"high":null,"kind":"point","display":"0.7","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"0.7"},{"value":0.3,"low":null,"high":null,"kind":"point","display":"0.3","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"0.3"},{"value":0.4,"low":null,"high":null,"kind":"point","display":"0.4","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"0.4"},{"value":0.22,"low":null,"high":null,"kind":"point","display":"0.22","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"0.22"}]},{"analyteId":"nitrate","name":"Nitrate","family":"inorganic","familyLabel":"Inorganic chemicals","casrn":"14797-55-8","whatItIs":"A compound from fertilizer runoff, septic systems, and erosion of natural deposits.","whyItMatters":"Levels above the federal limit can cause 'blue baby syndrome,' a serious oxygen-transport condition in infants.","measured":{"value":20,"low":0,"high":20,"kind":"range","display":"0–20","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 20"},"federalStandard":{"type":"MCL","value":10,"units":"mg/L","enforceable":true},"status":{"key":"over","label":"At or above the limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":2},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0.5900000000000001},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":20,"low":0,"high":20,"kind":"range","display":"0–20","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 20"},{"value":5.9,"low":0,"high":5.9,"kind":"range","display":"0–5.9","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 5.9"},{"value":0.6,"low":null,"high":null,"kind":"point","display":"0.6","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"0.6"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":9.5,"low":null,"high":null,"kind":"point","display":"9.5","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"9.5"},{"value":2.3,"low":null,"high":null,"kind":"point","display":"2.3","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"2.3"}]}]},{"family":"metal","familyLabel":"Metals","contaminants":[{"analyteId":"arsenic","name":"Arsenic","family":"metal","familyLabel":"Metals","casrn":"7440-38-2","whatItIs":"A naturally occurring element that also enters water from industry and agriculture.","whyItMatters":"A known human carcinogen; long-term exposure is linked to skin, bladder, and lung cancer.","measured":{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","censored":true,"detectionLimit":null,"rawVerbatim":"ND"},"federalStandard":null,"status":{"key":"none","label":"None detected"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]},{"analyteId":"barium","name":"Barium","family":"metal","familyLabel":"Metals","casrn":"7440-39-3","whatItIs":"A metal from erosion of natural deposits and industrial discharge.","whyItMatters":"Long-term exposure above the federal limit can raise blood pressure.","measured":{"value":0.13,"low":0,"high":0.13,"kind":"range","display":"0–0.13","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 0.13"},"federalStandard":{"type":"MCL","value":2,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0.065},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0.065},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0.065}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0.13,"low":0,"high":0.13,"kind":"range","display":"0–0.13","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 0.13"},{"value":0.13,"low":0,"high":0.13,"kind":"range","display":"0–0.13","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 0.13"},{"value":0.13,"low":null,"high":null,"kind":"point","display":"0.13","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"0.13"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]},{"analyteId":"boron","name":"Boron","family":"metal","familyLabel":"Metals","casrn":"7440-42-8","whatItIs":"A naturally occurring element from rock and soil.","whyItMatters":"No enforceable federal limit; the EPA has issued a health advisory level.","measured":{"value":3.4,"low":0.29,"high":3.4,"kind":"range","display":"0.29–3.4","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"0.29 - 3.4"},"federalStandard":{"type":"NL","value":1,"units":"mg/L","enforceable":false},"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":null},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":null},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":null}],"measurements":[{"value":0.13,"low":null,"high":null,"kind":"point","display":"0.13","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"0.13"},{"value":0.15,"low":null,"high":null,"kind":"point","display":"0.15","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"0.15"},{"value":3.4,"low":0.29,"high":3.4,"kind":"range","display":"0.29–3.4","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"0.29 - 3.4"},{"value":0.41,"low":0.11,"high":0.41,"kind":"range","display":"0.11–0.41","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"0.11 - 0.41"},{"value":1.33,"low":null,"high":null,"kind":"point","display":"1.33","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"1.33"},{"value":0.24,"low":null,"high":null,"kind":"point","display":"0.24","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"0.24"}]},{"analyteId":"copper","name":"Copper","family":"metal","familyLabel":"Metals","casrn":"7440-50-8","whatItIs":"A metal that enters water from corroding household plumbing.","whyItMatters":"Short-term exposure causes stomach distress; long-term exposure can damage the liver and kidneys.","measured":{"value":0.17,"low":null,"high":null,"kind":"point","display":"0.17","units":"mg/L","statisticType":"p90","samplingContext":"at_the_tap","censored":false,"detectionLimit":null,"rawVerbatim":"0.17"},"federalStandard":{"type":"AL","value":1.3,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0.17,"low":null,"high":null,"kind":"point","display":"0.17","units":"mg/L","statisticType":"p90","samplingContext":"at_the_tap","rawVerbatim":"0.17"},{"value":53,"low":null,"high":null,"kind":"point","display":"53","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:No. Sites Sampled","rawVerbatim":"53"}]},{"analyteId":"lead","name":"Lead","family":"metal","familyLabel":"Metals","casrn":null,"whatItIs":"A toxic metal that leaches into water from old service lines, solder, and plumbing fixtures.","whyItMatters":"There is no safe level of lead; it harms brain development in children and raises blood pressure in adults. The EPA sets an action level, not a health goal above zero.","measured":{"value":0.0037,"low":null,"high":null,"kind":"point","display":"0.0037","units":"mg/L","statisticType":"p90","samplingContext":"at_the_tap","censored":false,"detectionLimit":null,"rawVerbatim":"lead 90th-percentile 0.0037 mg/L (EPA SDWIS LCR, 1 round(s), 2023)"},"federalStandard":{"type":"AL","value":0.015,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0.0037,"low":null,"high":null,"kind":"point","display":"0.0037","units":"mg/L","statisticType":"p90","samplingContext":"at_the_tap","rawVerbatim":"lead 90th-percentile 0.0037 mg/L (EPA SDWIS LCR, 1 round(s), 2023)"}]},{"analyteId":"lithium","name":"Lithium","family":"metal","familyLabel":"Metals","casrn":"7439-93-2","whatItIs":"A naturally occurring element found in some groundwater.","whyItMatters":"No enforceable federal limit; on the EPA contaminant candidate list for further study.","measured":{"value":55.1,"low":0,"high":55.1,"kind":"range","display":"0–55.1","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-55.1"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":55.1,"low":0,"high":55.1,"kind":"range","display":"0–55.1","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-55.1"},{"value":16,"low":null,"high":null,"kind":"point","display":"16","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"16"}]},{"analyteId":"vanadium","name":"Vanadium","family":"metal","familyLabel":"Metals","casrn":"7440-62-2","whatItIs":null,"whyItMatters":null,"measured":{"value":19,"low":0,"high":19,"kind":"range","display":"0–19","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 19"},"federalStandard":{"type":"NL","value":50,"units":null,"enforceable":false},"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"","average":null,"range":null,"ratio":null},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"","average":null,"range":null,"ratio":null},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"","average":null,"range":null,"ratio":null}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":19,"low":0,"high":19,"kind":"range","display":"0–19","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 19"},{"value":3.9,"low":0,"high":3.9,"kind":"range","display":"0–3.9","units":null,"statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 3.9"},{"value":6.39,"low":null,"high":null,"kind":"point","display":"6.39","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"6.39"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]}]},{"family":"other","familyLabel":"Other","contaminants":[{"analyteId":"chromium","name":"Chromium","family":"other","familyLabel":"Other","casrn":null,"whatItIs":null,"whyItMatters":null,"measured":{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","censored":true,"detectionLimit":null,"rawVerbatim":"ND"},"federalStandard":null,"status":{"key":"none","label":"None detected"},"breakdowns":[{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]},{"analyteId":"pce","name":"Pce","family":"other","familyLabel":"Other","casrn":null,"whatItIs":null,"whyItMatters":null,"measured":{"value":1,"low":0,"high":1,"kind":"range","display":"0–1","units":null,"statisticType":"reported_level","samplingContext":"plant:GROUND WATER","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 1"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:COLORADO RIVER WATER","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"plant:GROUND WATER","label":"Ground Water","kind":"plant","units":"","average":null,"range":null,"ratio":null}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:STATE PROJECT WATER","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:COLORADO RIVER WATER","rawVerbatim":"ND"},{"value":1,"low":0,"high":1,"kind":"range","display":"0–1","units":null,"statisticType":"reported_level","samplingContext":"plant:GROUND WATER","rawVerbatim":"ND - 1"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:GROUND WATER","rawVerbatim":"ND"}]},{"analyteId":"tce","name":"Tce","family":"other","familyLabel":"Other","casrn":null,"whatItIs":null,"whyItMatters":null,"measured":{"value":1.1,"low":0,"high":1.1,"kind":"range","display":"0–1.1","units":null,"statisticType":"reported_level","samplingContext":"plant:GROUND WATER","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 1.1"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:COLORADO RIVER WATER","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"plant:GROUND WATER","label":"Ground Water","kind":"plant","units":"","average":null,"range":null,"ratio":null}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:STATE PROJECT WATER","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:COLORADO RIVER WATER","rawVerbatim":"ND"},{"value":1.1,"low":0,"high":1.1,"kind":"range","display":"0–1.1","units":null,"statisticType":"reported_level","samplingContext":"plant:GROUND WATER","rawVerbatim":"ND - 1.1"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:GROUND WATER","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]}]},{"family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","contaminants":[{"analyteId":"pfhxs","name":"Perfluorohexanesulfonic acid","family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","casrn":"355-46-4","whatItIs":"Perfluorohexanesulfonic acid, a PFAS 'forever chemical.'","whyItMatters":"Regulated by the EPA at 10 parts per trillion and included in the PFAS Hazard Index.","measured":{"value":0.0033,"low":0,"high":0.0033,"kind":"range","display":"0–0.0033","units":"ng/L","statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-0.0033"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0.0033,"low":0,"high":0.0033,"kind":"range","display":"0–0.0033","units":"ng/L","statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-0.0033"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ng/L","statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND"}]},{"analyteId":"pfhxa","name":"Perfluorohexanoic acid","family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","casrn":"307-24-4","whatItIs":"Perfluorohexanoic acid, a shorter-chain PFAS 'forever chemical.'","whyItMatters":"Monitored under EPA rules; persistent and widely detected.","measured":{"value":0.0038,"low":0,"high":0.0038,"kind":"range","display":"0–0.0038","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-0.0038"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":0.0038,"low":0,"high":0.0038,"kind":"range","display":"0–0.0038","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-0.0038"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND"}]},{"analyteId":"pfpea","name":"Perfluoropentanoic acid","family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","casrn":"2706-90-3","whatItIs":"Perfluoropentanoic acid, a shorter-chain PFAS 'forever chemical.'","whyItMatters":"Monitored under EPA rules; persistent in the environment.","measured":{"value":0.0061,"low":0,"high":0.0061,"kind":"range","display":"0–0.0061","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-0.0061"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":0.0061,"low":0,"high":0.0061,"kind":"range","display":"0–0.0061","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-0.0061"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND"}]},{"analyteId":"pfba","name":"PFBA","family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","casrn":"375-22-4","whatItIs":"Perfluorobutanoic acid, a shorter-chain PFAS 'forever chemical.'","whyItMatters":"Monitored under EPA rules; persistent in the environment and the human body.","measured":{"value":0.0076,"low":0,"high":0.0076,"kind":"range","display":"0–0.0076","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-0.0076"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":0.0076,"low":0,"high":0.0076,"kind":"range","display":"0–0.0076","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-0.0076"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND"}]},{"analyteId":"pfoa","name":"PFOA","family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","casrn":"335-67-1","whatItIs":"Perfluorooctanoic acid, a PFAS 'forever chemical' once used in nonstick and stain-resistant products.","whyItMatters":"Linked to cancer, liver damage, and immune effects; the EPA set an enforceable limit of 4 parts per trillion.","measured":{"value":4.3,"low":0,"high":4.3,"kind":"range","display":"0–4.3","units":"ng/L","statisticType":"average","samplingContext":"zone:Treated Average System Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 4.3"},"federalStandard":{"type":"NL","value":5.1,"units":"ng/L","enforceable":false},"status":{"key":"over","label":"At or above the limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"ng/L","average":null,"range":null,"ratio":75},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"ng/L","average":{"value":4.3,"display":"0–4.3"},"range":null,"ratio":1.075},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"ng/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ng/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ng/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":300,"low":0,"high":300,"kind":"range","display":"0–300","units":"ng/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 300"},{"value":4.3,"low":0,"high":4.3,"kind":"range","display":"0–4.3","units":"ng/L","statisticType":"average","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 4.3"},{"value":80,"low":null,"high":null,"kind":"point","display":"80","units":"ng/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"80"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ng/L","statisticType":"average","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]}]},{"family":"physical_aggregate","familyLabel":"Physical & aggregate","contaminants":[{"analyteId":"toc","name":"TOC","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"Total organic carbon — a measure of organic material dissolved in the water.","whyItMatters":"Not harmful itself, but it is the raw material that forms disinfection byproducts; removal is a treatment requirement.","measured":{"value":2600,"low":0,"high":2600,"kind":"range","display":"0–2600","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-2,600"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":2600,"low":0,"high":2600,"kind":"range","display":"0–2600","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-2,600"},{"value":1925,"low":null,"high":null,"kind":"point","display":"1925","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"1,925"}]},{"analyteId":"turbidity","name":"Turbidity","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"A measure of cloudiness from suspended particles in the water.","whyItMatters":"High turbidity can shelter microbes from disinfection; the EPA enforces it through a treatment-technique standard.","measured":{"value":0.08,"low":null,"high":null,"kind":"point","display":"0.08","units":"NTU","statisticType":"reported_level","samplingContext":"system","censored":false,"detectionLimit":null,"rawVerbatim":"0.08"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0.08,"low":null,"high":null,"kind":"point","display":"0.08","units":"NTU","statisticType":"reported_level","samplingContext":"system","rawVerbatim":"0.08"},{"value":0.05,"low":null,"high":null,"kind":"point","display":"0.05","units":"NTU","statisticType":"reported_level","samplingContext":"system","rawVerbatim":"0.05"}]}]},{"family":"radionuclide","familyLabel":"Radionuclides","contaminants":[{"analyteId":"gross_alpha","name":"Gross Alpha","family":"radionuclide","familyLabel":"Radionuclides","casrn":null,"whatItIs":"Gross alpha particle activity — a combined measure of alpha-emitting radioactive substances.","whyItMatters":"Long-term exposure above the federal limit increases cancer risk.","measured":{"value":7.5,"low":0,"high":7.5,"kind":"range","display":"0–7.5","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 7.5"},"federalStandard":{"type":"MCL","value":15,"units":"pCi/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"pCi/L","average":null,"range":null,"ratio":0.5},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"pCi/L","average":null,"range":null,"ratio":0.21333333333333335}],"measurements":[{"value":3.2,"low":0,"high":3.2,"kind":"range","display":"0–3.2","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND - 3.2"},{"value":7.5,"low":0,"high":7.5,"kind":"range","display":"0–7.5","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 7.5"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":3.84,"low":null,"high":null,"kind":"point","display":"3.84","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"3.84"}]},{"analyteId":"uranium","name":"Uranium","family":"radionuclide","familyLabel":"Radionuclides","casrn":"7440-61-1","whatItIs":"A naturally occurring radioactive metal from erosion of natural deposits.","whyItMatters":"Long-term exposure above the federal limit can damage the kidneys and increase cancer risk.","measured":{"value":16.8,"low":0,"high":16.8,"kind":"range","display":"0–16.8","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 16.8"},"federalStandard":{"type":"MCL","value":20,"units":"pCi/L","enforceable":true},"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"pCi/L","average":null,"range":null,"ratio":null},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"pCi/L","average":null,"range":null,"ratio":null}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":3.1,"low":2.8,"high":3.1,"kind":"range","display":"2.8–3.1","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"2.8 - 3.1"},{"value":16.8,"low":0,"high":16.8,"kind":"range","display":"0–16.8","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 16.8"},{"value":2.9,"low":null,"high":null,"kind":"point","display":"2.9","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"2.9"},{"value":4.71,"low":null,"high":null,"kind":"point","display":"4.71","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"4.71"}]}]}],"contaminants":[{"analyteId":"bromate","name":"Bromate","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":"15541-45-4","whatItIs":"A disinfection byproduct formed when bromide-containing water is treated with ozone.","whyItMatters":"Classified as a probable human carcinogen; the EPA sets a strict maximum contaminant level.","measured":{"value":19,"low":0,"high":19,"kind":"range","display":"0–19","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System Wide","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 19"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":19,"low":0,"high":19,"kind":"range","display":"0–19","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System Wide","rawVerbatim":"ND - 19"},{"value":7.9,"low":null,"high":null,"kind":"point","display":"7.9","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System Wide","rawVerbatim":"7.9"}]},{"analyteId":"perchlorate","name":"Perchlorate","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":"14797-73-0","whatItIs":"A chemical used in rocket fuel and fireworks that can also form during disinfection.","whyItMatters":"Can interfere with thyroid hormone production; has no national enforceable limit but is regulated in some states.","measured":{"value":9.4,"low":0,"high":9.4,"kind":"range","display":"0–9.4","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 9.4"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"","average":null,"range":null,"ratio":null},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"","average":null,"range":null,"ratio":null},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"","average":null,"range":null,"ratio":null}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":9.4,"low":0,"high":9.4,"kind":"range","display":"0–9.4","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 9.4"},{"value":2.9,"low":0,"high":2.9,"kind":"range","display":"0–2.9","units":null,"statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 2.9"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":3.3,"low":null,"high":null,"kind":"point","display":"3.3","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"3.3"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]},{"analyteId":"bromide","name":"Bromide","family":"inorganic","familyLabel":"Inorganic chemicals","casrn":"24959-67-9","whatItIs":"A naturally occurring salt found in source water.","whyItMatters":"Not directly regulated, but a precursor that increases formation of brominated disinfection byproducts.","measured":{"value":32,"low":0,"high":32,"kind":"range","display":"0–32","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-32"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":32,"low":0,"high":32,"kind":"range","display":"0–32","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-32"},{"value":15.3,"low":null,"high":null,"kind":"point","display":"15.3","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"15.3"}]},{"analyteId":"fluoride","name":"Fluoride","family":"inorganic","familyLabel":"Inorganic chemicals","casrn":"16984-48-8","whatItIs":"A mineral often added to drinking water to help prevent tooth decay.","whyItMatters":"Beneficial at low levels, but long-term exposure above the federal limit can cause bone disease and tooth mottling.","measured":{"value":2,"low":0.26,"high":2,"kind":"range","display":"0.26–2","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"0.26 - 2.0"},"federalStandard":{"type":"MCL","value":4,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0.5},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0.195},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0.1}],"measurements":[{"value":0.9,"low":0.6,"high":0.9,"kind":"range","display":"0.6–0.9","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"0.6 - 0.9"},{"value":0.4,"low":0.3,"high":0.4,"kind":"range","display":"0.3–0.4","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"0.3 - 0.4"},{"value":2,"low":0.26,"high":2,"kind":"range","display":"0.26–2","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"0.26 - 2.0"},{"value":0.78,"low":0,"high":0.78,"kind":"range","display":"0–0.78","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 0.78"},{"value":0.7,"low":null,"high":null,"kind":"point","display":"0.7","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"0.7"},{"value":0.3,"low":null,"high":null,"kind":"point","display":"0.3","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"0.3"},{"value":0.4,"low":null,"high":null,"kind":"point","display":"0.4","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"0.4"},{"value":0.22,"low":null,"high":null,"kind":"point","display":"0.22","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"0.22"}]},{"analyteId":"nitrate","name":"Nitrate","family":"inorganic","familyLabel":"Inorganic chemicals","casrn":"14797-55-8","whatItIs":"A compound from fertilizer runoff, septic systems, and erosion of natural deposits.","whyItMatters":"Levels above the federal limit can cause 'blue baby syndrome,' a serious oxygen-transport condition in infants.","measured":{"value":20,"low":0,"high":20,"kind":"range","display":"0–20","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 20"},"federalStandard":{"type":"MCL","value":10,"units":"mg/L","enforceable":true},"status":{"key":"over","label":"At or above the limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":2},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0.5900000000000001},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":20,"low":0,"high":20,"kind":"range","display":"0–20","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 20"},{"value":5.9,"low":0,"high":5.9,"kind":"range","display":"0–5.9","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 5.9"},{"value":0.6,"low":null,"high":null,"kind":"point","display":"0.6","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"0.6"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":9.5,"low":null,"high":null,"kind":"point","display":"9.5","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"9.5"},{"value":2.3,"low":null,"high":null,"kind":"point","display":"2.3","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"2.3"}]},{"analyteId":"arsenic","name":"Arsenic","family":"metal","familyLabel":"Metals","casrn":"7440-38-2","whatItIs":"A naturally occurring element that also enters water from industry and agriculture.","whyItMatters":"A known human carcinogen; long-term exposure is linked to skin, bladder, and lung cancer.","measured":{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","censored":true,"detectionLimit":null,"rawVerbatim":"ND"},"federalStandard":null,"status":{"key":"none","label":"None detected"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]},{"analyteId":"barium","name":"Barium","family":"metal","familyLabel":"Metals","casrn":"7440-39-3","whatItIs":"A metal from erosion of natural deposits and industrial discharge.","whyItMatters":"Long-term exposure above the federal limit can raise blood pressure.","measured":{"value":0.13,"low":0,"high":0.13,"kind":"range","display":"0–0.13","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 0.13"},"federalStandard":{"type":"MCL","value":2,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0.065},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0.065},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0.065}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0.13,"low":0,"high":0.13,"kind":"range","display":"0–0.13","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 0.13"},{"value":0.13,"low":0,"high":0.13,"kind":"range","display":"0–0.13","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 0.13"},{"value":0.13,"low":null,"high":null,"kind":"point","display":"0.13","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"0.13"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]},{"analyteId":"boron","name":"Boron","family":"metal","familyLabel":"Metals","casrn":"7440-42-8","whatItIs":"A naturally occurring element from rock and soil.","whyItMatters":"No enforceable federal limit; the EPA has issued a health advisory level.","measured":{"value":3.4,"low":0.29,"high":3.4,"kind":"range","display":"0.29–3.4","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"0.29 - 3.4"},"federalStandard":{"type":"NL","value":1,"units":"mg/L","enforceable":false},"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":null},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":null},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":null}],"measurements":[{"value":0.13,"low":null,"high":null,"kind":"point","display":"0.13","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"0.13"},{"value":0.15,"low":null,"high":null,"kind":"point","display":"0.15","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"0.15"},{"value":3.4,"low":0.29,"high":3.4,"kind":"range","display":"0.29–3.4","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"0.29 - 3.4"},{"value":0.41,"low":0.11,"high":0.41,"kind":"range","display":"0.11–0.41","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"0.11 - 0.41"},{"value":1.33,"low":null,"high":null,"kind":"point","display":"1.33","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"1.33"},{"value":0.24,"low":null,"high":null,"kind":"point","display":"0.24","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"0.24"}]},{"analyteId":"copper","name":"Copper","family":"metal","familyLabel":"Metals","casrn":"7440-50-8","whatItIs":"A metal that enters water from corroding household plumbing.","whyItMatters":"Short-term exposure causes stomach distress; long-term exposure can damage the liver and kidneys.","measured":{"value":0.17,"low":null,"high":null,"kind":"point","display":"0.17","units":"mg/L","statisticType":"p90","samplingContext":"at_the_tap","censored":false,"detectionLimit":null,"rawVerbatim":"0.17"},"federalStandard":{"type":"AL","value":1.3,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0.17,"low":null,"high":null,"kind":"point","display":"0.17","units":"mg/L","statisticType":"p90","samplingContext":"at_the_tap","rawVerbatim":"0.17"},{"value":53,"low":null,"high":null,"kind":"point","display":"53","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:No. Sites Sampled","rawVerbatim":"53"}]},{"analyteId":"lead","name":"Lead","family":"metal","familyLabel":"Metals","casrn":null,"whatItIs":"A toxic metal that leaches into water from old service lines, solder, and plumbing fixtures.","whyItMatters":"There is no safe level of lead; it harms brain development in children and raises blood pressure in adults. The EPA sets an action level, not a health goal above zero.","measured":{"value":0.0037,"low":null,"high":null,"kind":"point","display":"0.0037","units":"mg/L","statisticType":"p90","samplingContext":"at_the_tap","censored":false,"detectionLimit":null,"rawVerbatim":"lead 90th-percentile 0.0037 mg/L (EPA SDWIS LCR, 1 round(s), 2023)"},"federalStandard":{"type":"AL","value":0.015,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0.0037,"low":null,"high":null,"kind":"point","display":"0.0037","units":"mg/L","statisticType":"p90","samplingContext":"at_the_tap","rawVerbatim":"lead 90th-percentile 0.0037 mg/L (EPA SDWIS LCR, 1 round(s), 2023)"}]},{"analyteId":"lithium","name":"Lithium","family":"metal","familyLabel":"Metals","casrn":"7439-93-2","whatItIs":"A naturally occurring element found in some groundwater.","whyItMatters":"No enforceable federal limit; on the EPA contaminant candidate list for further study.","measured":{"value":55.1,"low":0,"high":55.1,"kind":"range","display":"0–55.1","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-55.1"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":55.1,"low":0,"high":55.1,"kind":"range","display":"0–55.1","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-55.1"},{"value":16,"low":null,"high":null,"kind":"point","display":"16","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"16"}]},{"analyteId":"vanadium","name":"Vanadium","family":"metal","familyLabel":"Metals","casrn":"7440-62-2","whatItIs":null,"whyItMatters":null,"measured":{"value":19,"low":0,"high":19,"kind":"range","display":"0–19","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 19"},"federalStandard":{"type":"NL","value":50,"units":null,"enforceable":false},"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"","average":null,"range":null,"ratio":null},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"","average":null,"range":null,"ratio":null},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"","average":null,"range":null,"ratio":null}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":19,"low":0,"high":19,"kind":"range","display":"0–19","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 19"},{"value":3.9,"low":0,"high":3.9,"kind":"range","display":"0–3.9","units":null,"statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 3.9"},{"value":6.39,"low":null,"high":null,"kind":"point","display":"6.39","units":null,"statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"6.39"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]},{"analyteId":"chromium","name":"Chromium","family":"other","familyLabel":"Other","casrn":null,"whatItIs":null,"whyItMatters":null,"measured":{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","censored":true,"detectionLimit":null,"rawVerbatim":"ND"},"federalStandard":null,"status":{"key":"none","label":"None detected"},"breakdowns":[{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]},{"analyteId":"pce","name":"Pce","family":"other","familyLabel":"Other","casrn":null,"whatItIs":null,"whyItMatters":null,"measured":{"value":1,"low":0,"high":1,"kind":"range","display":"0–1","units":null,"statisticType":"reported_level","samplingContext":"plant:GROUND WATER","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 1"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:COLORADO RIVER WATER","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"plant:GROUND WATER","label":"Ground Water","kind":"plant","units":"","average":null,"range":null,"ratio":null}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:STATE PROJECT WATER","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:COLORADO RIVER WATER","rawVerbatim":"ND"},{"value":1,"low":0,"high":1,"kind":"range","display":"0–1","units":null,"statisticType":"reported_level","samplingContext":"plant:GROUND WATER","rawVerbatim":"ND - 1"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:GROUND WATER","rawVerbatim":"ND"}]},{"analyteId":"tce","name":"Tce","family":"other","familyLabel":"Other","casrn":null,"whatItIs":null,"whyItMatters":null,"measured":{"value":1.1,"low":0,"high":1.1,"kind":"range","display":"0–1.1","units":null,"statisticType":"reported_level","samplingContext":"plant:GROUND WATER","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 1.1"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:COLORADO RIVER WATER","label":"Colorado River Water","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":0},{"context":"plant:GROUND WATER","label":"Ground Water","kind":"plant","units":"","average":null,"range":null,"ratio":null}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:STATE PROJECT WATER","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:COLORADO RIVER WATER","rawVerbatim":"ND"},{"value":1.1,"low":0,"high":1.1,"kind":"range","display":"0–1.1","units":null,"statisticType":"reported_level","samplingContext":"plant:GROUND WATER","rawVerbatim":"ND - 1.1"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:GROUND WATER","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]},{"analyteId":"pfhxs","name":"Perfluorohexanesulfonic acid","family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","casrn":"355-46-4","whatItIs":"Perfluorohexanesulfonic acid, a PFAS 'forever chemical.'","whyItMatters":"Regulated by the EPA at 10 parts per trillion and included in the PFAS Hazard Index.","measured":{"value":0.0033,"low":0,"high":0.0033,"kind":"range","display":"0–0.0033","units":"ng/L","statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-0.0033"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0.0033,"low":0,"high":0.0033,"kind":"range","display":"0–0.0033","units":"ng/L","statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-0.0033"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ng/L","statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND"}]},{"analyteId":"pfhxa","name":"Perfluorohexanoic acid","family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","casrn":"307-24-4","whatItIs":"Perfluorohexanoic acid, a shorter-chain PFAS 'forever chemical.'","whyItMatters":"Monitored under EPA rules; persistent and widely detected.","measured":{"value":0.0038,"low":0,"high":0.0038,"kind":"range","display":"0–0.0038","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-0.0038"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":0.0038,"low":0,"high":0.0038,"kind":"range","display":"0–0.0038","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-0.0038"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND"}]},{"analyteId":"pfpea","name":"Perfluoropentanoic acid","family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","casrn":"2706-90-3","whatItIs":"Perfluoropentanoic acid, a shorter-chain PFAS 'forever chemical.'","whyItMatters":"Monitored under EPA rules; persistent in the environment.","measured":{"value":0.0061,"low":0,"high":0.0061,"kind":"range","display":"0–0.0061","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-0.0061"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":0.0061,"low":0,"high":0.0061,"kind":"range","display":"0–0.0061","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-0.0061"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND"}]},{"analyteId":"pfba","name":"PFBA","family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","casrn":"375-22-4","whatItIs":"Perfluorobutanoic acid, a shorter-chain PFAS 'forever chemical.'","whyItMatters":"Monitored under EPA rules; persistent in the environment and the human body.","measured":{"value":0.0076,"low":0,"high":0.0076,"kind":"range","display":"0–0.0076","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-0.0076"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":0.0076,"low":0,"high":0.0076,"kind":"range","display":"0–0.0076","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-0.0076"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND"}]},{"analyteId":"pfoa","name":"PFOA","family":"pfas","familyLabel":"PFAS (\"forever chemicals\")","casrn":"335-67-1","whatItIs":"Perfluorooctanoic acid, a PFAS 'forever chemical' once used in nonstick and stain-resistant products.","whyItMatters":"Linked to cancer, liver damage, and immune effects; the EPA set an enforceable limit of 4 parts per trillion.","measured":{"value":4.3,"low":0,"high":4.3,"kind":"range","display":"0–4.3","units":"ng/L","statisticType":"average","samplingContext":"zone:Treated Average System Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 4.3"},"federalStandard":{"type":"NL","value":5.1,"units":"ng/L","enforceable":false},"status":{"key":"over","label":"At or above the limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"ng/L","average":null,"range":null,"ratio":75},{"context":"zone:Treated Average System Water","label":"Treated Average System Water","kind":"zone","units":"ng/L","average":{"value":4.3,"display":"0–4.3"},"range":null,"ratio":1.075},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"ng/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ng/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ng/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":300,"low":0,"high":300,"kind":"range","display":"0–300","units":"ng/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 300"},{"value":4.3,"low":0,"high":4.3,"kind":"range","display":"0–4.3","units":"ng/L","statisticType":"average","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND - 4.3"},{"value":80,"low":null,"high":null,"kind":"point","display":"80","units":"ng/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"80"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ng/L","statisticType":"average","samplingContext":"zone:Treated Average System Water","rawVerbatim":"ND"}]},{"analyteId":"toc","name":"TOC","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"Total organic carbon — a measure of organic material dissolved in the water.","whyItMatters":"Not harmful itself, but it is the raw material that forms disinfection byproducts; removal is a treatment requirement.","measured":{"value":2600,"low":0,"high":2600,"kind":"range","display":"0–2600","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","censored":false,"detectionLimit":null,"rawVerbatim":"ND-2,600"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":2600,"low":0,"high":2600,"kind":"range","display":"0–2600","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"ND-2,600"},{"value":1925,"low":null,"high":null,"kind":"point","display":"1925","units":null,"statisticType":"reported_level","samplingContext":"zone:Distribution System","rawVerbatim":"1,925"}]},{"analyteId":"turbidity","name":"Turbidity","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"A measure of cloudiness from suspended particles in the water.","whyItMatters":"High turbidity can shelter microbes from disinfection; the EPA enforces it through a treatment-technique standard.","measured":{"value":0.08,"low":null,"high":null,"kind":"point","display":"0.08","units":"NTU","statisticType":"reported_level","samplingContext":"system","censored":false,"detectionLimit":null,"rawVerbatim":"0.08"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0.08,"low":null,"high":null,"kind":"point","display":"0.08","units":"NTU","statisticType":"reported_level","samplingContext":"system","rawVerbatim":"0.08"},{"value":0.05,"low":null,"high":null,"kind":"point","display":"0.05","units":"NTU","statisticType":"reported_level","samplingContext":"system","rawVerbatim":"0.05"}]},{"analyteId":"gross_alpha","name":"Gross Alpha","family":"radionuclide","familyLabel":"Radionuclides","casrn":null,"whatItIs":"Gross alpha particle activity — a combined measure of alpha-emitting radioactive substances.","whyItMatters":"Long-term exposure above the federal limit increases cancer risk.","measured":{"value":7.5,"low":0,"high":7.5,"kind":"range","display":"0–7.5","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 7.5"},"federalStandard":{"type":"MCL","value":15,"units":"pCi/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"pCi/L","average":null,"range":null,"ratio":0.5},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"pCi/L","average":null,"range":null,"ratio":0.21333333333333335}],"measurements":[{"value":3.2,"low":0,"high":3.2,"kind":"range","display":"0–3.2","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND - 3.2"},{"value":7.5,"low":0,"high":7.5,"kind":"range","display":"0–7.5","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 7.5"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"ND"},{"value":3.84,"low":null,"high":null,"kind":"point","display":"3.84","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"3.84"}]},{"analyteId":"uranium","name":"Uranium","family":"radionuclide","familyLabel":"Radionuclides","casrn":"7440-61-1","whatItIs":"A naturally occurring radioactive metal from erosion of natural deposits.","whyItMatters":"Long-term exposure above the federal limit can damage the kidneys and increase cancer risk.","measured":{"value":16.8,"low":0,"high":16.8,"kind":"range","display":"0–16.8","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","censored":false,"detectionLimit":null,"rawVerbatim":"ND - 16.8"},"federalStandard":{"type":"MCL","value":20,"units":"pCi/L","enforceable":true},"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Ground Water","label":"Ground Water","kind":"plant","units":"pCi/L","average":null,"range":null,"ratio":null},{"context":"plant:Colorado River Water","label":"Colorado River Water","kind":"plant","units":"pCi/L","average":null,"range":null,"ratio":null}],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:State Project Water","rawVerbatim":"ND"},{"value":3.1,"low":2.8,"high":3.1,"kind":"range","display":"2.8–3.1","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"2.8 - 3.1"},{"value":16.8,"low":0,"high":16.8,"kind":"range","display":"0–16.8","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"ND - 16.8"},{"value":2.9,"low":null,"high":null,"kind":"point","display":"2.9","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Colorado River Water","rawVerbatim":"2.9"},{"value":4.71,"low":null,"high":null,"kind":"point","display":"4.71","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Ground Water","rawVerbatim":"4.71"}]}]}}