{"dataset":{"name":"U.S. Drinking Water Quality — Contaminant Measurements","license":"https://creativecommons.org/licenses/by/4.0/","homepage":"https://www.thewatermap.com"},"meta":{"generatedAt":"2026-06-04T01:44:13.257Z"},"system":{"slug":"ca__crescenta-valley-cwd__CA1910028__2021","name":"Crescenta Valley Cwd — La Crescenta, Ca","state":"CA","year":2021,"url":"https://www.thewatermap.com/water/ca/crescenta-valley-cwd-la-crescenta-ca/2021","apiUrl":"https://www.thewatermap.com/api/water/ca/crescenta-valley-cwd-la-crescenta-ca/2021","markdownUrl":"https://www.thewatermap.com/water/ca/crescenta-valley-cwd-la-crescenta-ca/2021/llms.txt","coordinates":{"latitude":34.2225882,"longitude":-118.243128},"contaminantsMeasured":29,"contaminantsWithFederalLimit":8,"contaminantsAtOrAboveLimit":1,"contaminantsApproachingLimit":1,"source":{"type":"Consumer Confidence Report (CCR)","description":"Figures are transcribed from the water utility's own annual Consumer Confidence Report, cross-checked by a second model, and approved by a person before publishing."},"families":[{"family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","contaminants":[{"analyteId":"bromate","name":"Bromate","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":"15541-45-4","whatItIs":"A disinfection byproduct formed when bromide-containing water is treated with ozone.","whyItMatters":"Classified as a probable human carcinogen; the EPA sets a strict maximum contaminant level.","measured":{"value":7.6,"low":0,"high":7.6,"kind":"range","display":"0–7.6","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"ND–7.6"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"},{"value":7.6,"low":0,"high":7.6,"kind":"range","display":"0–7.6","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND–7.6"}]},{"analyteId":"chlorate","name":"Chlorate","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":"14866-68-3","whatItIs":"A byproduct that can form during disinfection, especially when hypochlorite solutions degrade.","whyItMatters":"Has no enforceable federal limit but is on the EPA contaminant candidate list; high levels can affect the thyroid.","measured":{"value":88,"low":null,"high":null,"kind":"point","display":"88","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"88⁵"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":88,"low":null,"high":null,"kind":"point","display":"88","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"88⁵"},{"value":88,"low":88,"high":88,"kind":"range","display":"88–88","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"88–88⁵"}]},{"analyteId":"haa5","name":"HAA5","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":null,"whatItIs":"Haloacetic acids — a group of five disinfection byproducts formed when disinfectants react with organic matter.","whyItMatters":"Long-term exposure above the federal limit is associated with an increased cancer risk.","measured":{"value":19,"low":5.9,"high":19,"kind":"range","display":"5.9–19","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"5.9–19⁸"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":5.9,"high":19,"display":"5.9–19"},"ratio":0.31666666666666665},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":{"low":1.5,"high":14,"display":"1.5–14"},"ratio":0.23333333333333334}],"measurements":[{"value":9.8,"low":null,"high":null,"kind":"point","display":"9.8","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"9.8⁹,¹⁰"},{"value":19,"low":5.9,"high":19,"kind":"range","display":"5.9–19","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"5.9–19⁸"},{"value":14,"low":1.5,"high":14,"kind":"range","display":"1.5–14","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"1.5–14⁹,¹⁰"},{"value":12.4,"low":null,"high":null,"kind":"point","display":"12.4","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"12.4⁸"}]},{"analyteId":"ndma","name":"NDMA","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":"62-75-9","whatItIs":null,"whyItMatters":null,"measured":{"value":3.3,"low":0,"high":3.3,"kind":"range","display":"0–3.3","units":"ng/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"ND–3.3⁵"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":3.3,"low":0,"high":3.3,"kind":"range","display":"0–3.3","units":"ng/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND–3.3⁵"}]},{"analyteId":"tthm","name":"TTHM","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":null,"whatItIs":"Total trihalomethanes — a group of four chemicals (including chloroform) formed when chlorine reacts with natural organic matter.","whyItMatters":"Long-term exposure above the federal limit is linked to liver, kidney, and central-nervous-system effects and increased cancer risk.","measured":{"value":69,"low":26,"high":69,"kind":"range","display":"26–69","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"26.0–69.0⁸"},"federalStandard":null,"status":{"key":"approaching","label":"Approaching the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":26,"high":69,"display":"26–69"},"ratio":0.8625},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":{"low":11,"high":42,"display":"11–42"},"ratio":0.525}],"measurements":[{"value":46.5,"low":null,"high":null,"kind":"point","display":"46.5","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"46.5⁸"},{"value":34,"low":null,"high":null,"kind":"point","display":"34","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"34"},{"value":69,"low":26,"high":69,"kind":"range","display":"26–69","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"26.0–69.0⁸"},{"value":42,"low":11,"high":42,"kind":"range","display":"11–42","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"11–42"}]}]},{"family":"inorganic","familyLabel":"Inorganic chemicals","contaminants":[{"analyteId":"fluoride","name":"Fluoride","family":"inorganic","familyLabel":"Inorganic chemicals","casrn":"16984-48-8","whatItIs":"A mineral often added to drinking water to help prevent tooth decay.","whyItMatters":"Beneficial at low levels, but long-term exposure above the federal limit can cause bone disease and tooth mottling.","measured":{"value":0.9,"low":0.4,"high":0.9,"kind":"range","display":"0.4–0.9","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"0.4–0.9³"},"federalStandard":{"type":"MCL","value":4,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":0.4,"high":0.9,"display":"0.4–0.9"},"ratio":0.225},{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":0.27,"high":0.49,"display":"0.27–0.49"},"ratio":0.1225}],"measurements":[{"value":0.7,"low":null,"high":null,"kind":"point","display":"0.7","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.7"},{"value":0.44,"low":null,"high":null,"kind":"point","display":"0.44","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.44²"},{"value":0.49,"low":0.27,"high":0.49,"kind":"range","display":"0.27–0.49","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.27–0.49"},{"value":0.9,"low":0.4,"high":0.9,"kind":"range","display":"0.4–0.9","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.4–0.9³"}]},{"analyteId":"nitrate","name":"Nitrate","family":"inorganic","familyLabel":"Inorganic chemicals","casrn":"14797-55-8","whatItIs":"A compound from fertilizer runoff, septic systems, and erosion of natural deposits.","whyItMatters":"Levels above the federal limit can cause 'blue baby syndrome,' a serious oxygen-transport condition in infants.","measured":{"value":33.1,"low":16.1,"high":33.1,"kind":"range","display":"16.1–33.1","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"16.1–33.1¹²"},"federalStandard":{"type":"MCL","value":10,"units":"mg/L","enforceable":true},"status":{"key":"over","label":"At or above the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":16.1,"high":33.1,"display":"16.1–33.1"},"ratio":3.31},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":22.6,"low":null,"high":null,"kind":"point","display":"22.6","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"22.6¹²"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"},{"value":33.1,"low":16.1,"high":33.1,"kind":"range","display":"16.1–33.1","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"16.1–33.1¹²"}]}]},{"family":"metal","familyLabel":"Metals","contaminants":[{"analyteId":"aluminum","name":"Aluminum","family":"metal","familyLabel":"Metals","casrn":"7429-90-5","whatItIs":"A common element sometimes used as a treatment coagulant.","whyItMatters":"Regulated only as a secondary (cosmetic) standard; high levels can discolor water.","measured":{"value":0.24,"low":0.052,"high":0.24,"kind":"range","display":"0.052–0.24","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"0.052–0.24¹"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":0.052,"high":0.24,"display":"0.052–0.24"},"ratio":null},{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":null}],"measurements":[{"value":0.156,"low":null,"high":null,"kind":"point","display":"0.156","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.156¹"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND"},{"value":0.24,"low":0.052,"high":0.24,"kind":"range","display":"0.052–0.24","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.052–0.24¹"}]},{"analyteId":"arsenic","name":"Arsenic","family":"metal","familyLabel":"Metals","casrn":"7440-38-2","whatItIs":"A naturally occurring element that also enters water from industry and agriculture.","whyItMatters":"A known human carcinogen; long-term exposure is linked to skin, bladder, and lung cancer.","measured":{"value":5.1,"low":0,"high":5.1,"kind":"range","display":"0–5.1","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"ND–5.10"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":5.1,"low":0,"high":5.1,"kind":"range","display":"0–5.1","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND–5.10"},{"value":0.09,"low":null,"high":null,"kind":"point","display":"0.09","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.09"}]},{"analyteId":"barium","name":"Barium","family":"metal","familyLabel":"Metals","casrn":"7440-39-3","whatItIs":"A metal from erosion of natural deposits and industrial discharge.","whyItMatters":"Long-term exposure above the federal limit can raise blood pressure.","measured":{"value":0.13,"low":0,"high":0.13,"kind":"range","display":"0–0.13","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"ND–0.13"},"federalStandard":{"type":"MCL","value":2,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":0,"high":0.13,"display":"0–0.13"},"ratio":0.065},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":0.107,"high":0.107,"display":"0.107–0.107"},"ratio":0.0535}],"measurements":[{"value":0.107,"low":0.107,"high":0.107,"kind":"range","display":"0.107–0.107","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.107–0.107"},{"value":0.107,"low":null,"high":null,"kind":"point","display":"0.107","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.107"},{"value":0.13,"low":0,"high":0.13,"kind":"range","display":"0–0.13","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND–0.13"},{"value":0.1,"low":null,"high":null,"kind":"point","display":"0.1","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.1"}]},{"analyteId":"boron","name":"Boron","family":"metal","familyLabel":"Metals","casrn":"7440-42-8","whatItIs":"A naturally occurring element from rock and soil.","whyItMatters":"No enforceable federal limit; the EPA has issued a health advisory level.","measured":{"value":140,"low":0,"high":140,"kind":"range","display":"0–140","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"ND–140"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":0,"high":140,"display":"0–140"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":{"low":140,"high":140,"display":"140–140"},"ratio":null}],"measurements":[{"value":140,"low":0,"high":140,"kind":"range","display":"0–140","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND–140"},{"value":140,"low":null,"high":null,"kind":"point","display":"140","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"140"},{"value":20,"low":null,"high":null,"kind":"point","display":"20","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"20"},{"value":140,"low":140,"high":140,"kind":"range","display":"140–140","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"140–140"}]},{"analyteId":"calcium","name":"Calcium","family":"metal","familyLabel":"Metals","casrn":"7440-70-2","whatItIs":"A naturally occurring mineral that contributes to water hardness.","whyItMatters":"Not federally regulated for health; affects scaling and taste.","measured":{"value":96,"low":35,"high":96,"kind":"range","display":"35–96","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"35–96"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":35,"high":96,"display":"35–96"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":68,"high":71,"display":"68–71"},"ratio":null}],"measurements":[{"value":71,"low":68,"high":71,"kind":"range","display":"68–71","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"68–71"},{"value":70,"low":null,"high":null,"kind":"point","display":"70","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"70"},{"value":81,"low":null,"high":null,"kind":"point","display":"81","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"81"},{"value":96,"low":35,"high":96,"kind":"range","display":"35–96","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"35–96"}]},{"analyteId":"chromium_hex","name":"Chromium, Hexavalent","family":"metal","familyLabel":"Metals","casrn":"18540-29-9","whatItIs":"Hexavalent chromium ('chromium-6') — the more toxic form of chromium.","whyItMatters":"A known carcinogen by inhalation; regulated nationally only within the total-chromium limit, with stricter limits in some states.","measured":{"value":2,"low":0.32,"high":2,"kind":"range","display":"0.32–2","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"0.32–2.0"},"federalStandard":{"type":"PHG","value":0.02,"units":"ug/L","enforceable":false},"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":0.32,"high":2,"display":"0.32–2"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":null,"ratio":null}],"measurements":[{"value":0.67,"low":null,"high":null,"kind":"point","display":"0.67","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.67"},{"value":2,"low":0.32,"high":2,"kind":"range","display":"0.32–2","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.32–2.0"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"}]},{"analyteId":"copper","name":"Copper","family":"metal","familyLabel":"Metals","casrn":"7440-50-8","whatItIs":"A metal that enters water from corroding household plumbing.","whyItMatters":"Short-term exposure causes stomach distress; long-term exposure can damage the liver and kidneys.","measured":{"value":315,"low":null,"high":null,"kind":"point","display":"315","units":"ug/L","statisticType":"p90","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"315"},"federalStandard":{"type":"AL","value":1300,"units":"ug/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":315,"low":null,"high":null,"kind":"point","display":"315","units":"ug/L","statisticType":"p90","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"315"}]},{"analyteId":"lead","name":"Lead","family":"metal","familyLabel":"Metals","casrn":"7439-92-1","whatItIs":"A toxic metal that leaches into water from old service lines, solder, and plumbing fixtures.","whyItMatters":"There is no safe level of lead; it harms brain development in children and raises blood pressure in adults. The EPA sets an action level, not a health goal above zero.","measured":{"value":2.1,"low":null,"high":null,"kind":"point","display":"2.1","units":"ug/L","statisticType":"p90","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"2.1"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":2.1,"low":null,"high":null,"kind":"point","display":"2.1","units":"ug/L","statisticType":"p90","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"2.1"}]},{"analyteId":"magnesium","name":"Magnesium","family":"metal","familyLabel":"Metals","casrn":"7439-95-4","whatItIs":"A naturally occurring mineral that contributes to water hardness.","whyItMatters":"Not federally regulated for health; affects scaling and taste.","measured":{"value":31,"low":11,"high":31,"kind":"range","display":"11–31","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"11–31"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":11,"high":31,"display":"11–31"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":25,"high":26,"display":"25–26"},"ratio":null}],"measurements":[{"value":31,"low":11,"high":31,"kind":"range","display":"11–31","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"11–31"},{"value":27,"low":null,"high":null,"kind":"point","display":"27","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"27"},{"value":26,"low":null,"high":null,"kind":"point","display":"26","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"26"},{"value":26,"low":25,"high":26,"kind":"range","display":"25–26","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"25–26"}]},{"analyteId":"potassium","name":"Potassium","family":"metal","familyLabel":"Metals","casrn":"7440-09-7","whatItIs":"A naturally occurring mineral from rock and soil.","whyItMatters":"Not federally regulated for health.","measured":{"value":4.8,"low":4.5,"high":4.8,"kind":"range","display":"4.5–4.8","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"4.5–4.8"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":4.5,"high":4.8,"display":"4.5–4.8"},"ratio":null},{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":2.6,"high":3.9,"display":"2.6–3.9"},"ratio":null}],"measurements":[{"value":3.9,"low":2.6,"high":3.9,"kind":"range","display":"2.6–3.9","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"2.6–3.9"},{"value":3.3,"low":null,"high":null,"kind":"point","display":"3.3","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"3.3"},{"value":4.8,"low":4.5,"high":4.8,"kind":"range","display":"4.5–4.8","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"4.5–4.8"},{"value":4.6,"low":null,"high":null,"kind":"point","display":"4.6","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"4.6"}]},{"analyteId":"sodium","name":"Sodium","family":"metal","familyLabel":"Metals","casrn":"7440-23-5","whatItIs":"A naturally occurring salt component.","whyItMatters":"Not federally regulated for health; relevant for people on sodium-restricted diets.","measured":{"value":103,"low":98,"high":103,"kind":"range","display":"98–103","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"98–103"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":98,"high":103,"display":"98–103"},"ratio":null},{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":17,"high":41,"display":"17–41"},"ratio":null}],"measurements":[{"value":35,"low":null,"high":null,"kind":"point","display":"35","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"35"},{"value":100,"low":null,"high":null,"kind":"point","display":"100","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"100"},{"value":41,"low":17,"high":41,"kind":"range","display":"17–41","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"17–41"},{"value":103,"low":98,"high":103,"kind":"range","display":"98–103","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"98–103"}]},{"analyteId":"vanadium","name":"Vanadium","family":"metal","familyLabel":"Metals","casrn":"7440-62-2","whatItIs":null,"whyItMatters":null,"measured":{"value":4.8,"low":0,"high":4.8,"kind":"range","display":"0–4.8","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"ND–4.8"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":0,"high":4.8,"display":"0–4.8"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":null,"ratio":null}],"measurements":[{"value":4,"low":null,"high":null,"kind":"point","display":"4","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"4"},{"value":4.8,"low":0,"high":4.8,"kind":"range","display":"0–4.8","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND–4.8"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"}]}]},{"family":"other","familyLabel":"Other","contaminants":[{"analyteId":"pce","name":"Pce","family":"other","familyLabel":"Other","casrn":null,"whatItIs":null,"whyItMatters":null,"measured":{"value":0.45,"low":0,"high":0.45,"kind":"range","display":"0–0.45","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"ND–0.45¹²"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":0,"high":0.45,"display":"0–0.45"},"ratio":0.09000000000000001},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":0.45,"low":0,"high":0.45,"kind":"range","display":"0–0.45","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND–0.45¹²"},{"value":0.29,"low":null,"high":null,"kind":"point","display":"0.29","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.29¹²"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"}]}]},{"family":"physical_aggregate","familyLabel":"Physical & aggregate","contaminants":[{"analyteId":"alkalinity","name":"Alkalinity","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"A measure of the water's capacity to neutralize acids.","whyItMatters":"Not federally regulated for health; relevant to corrosion control and treatment.","measured":{"value":180,"low":110,"high":180,"kind":"range","display":"110–180","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"110–180"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":110,"high":180,"display":"110–180"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":126,"high":128,"display":"126–128"},"ratio":null}],"measurements":[{"value":127,"low":null,"high":null,"kind":"point","display":"127","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"127"},{"value":128,"low":126,"high":128,"kind":"range","display":"126–128","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"126–128"},{"value":180,"low":110,"high":180,"kind":"range","display":"110–180","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"110–180"},{"value":151,"low":null,"high":null,"kind":"point","display":"151","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"151"}]},{"analyteId":"bicarbonate","name":"Bicarbonate","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":"71-52-3","whatItIs":null,"whyItMatters":null,"measured":{"value":180,"low":110,"high":180,"kind":"range","display":"110–180","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"110–180"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":180,"low":110,"high":180,"kind":"range","display":"110–180","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"110–180"},{"value":151,"low":null,"high":null,"kind":"point","display":"151","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"151"}]},{"analyteId":"hardness","name":"Hardness","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"A measure of dissolved calcium and magnesium minerals.","whyItMatters":"Not federally regulated for health; affects scaling, soap use, and taste.","measured":{"value":360,"low":130,"high":360,"kind":"range","display":"130–360","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"130–360"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":130,"high":360,"display":"130–360"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":277,"high":281,"display":"277–281"},"ratio":null}],"measurements":[{"value":279,"low":null,"high":null,"kind":"point","display":"279","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"279"},{"value":360,"low":130,"high":360,"kind":"range","display":"130–360","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"130–360"},{"value":313,"low":null,"high":null,"kind":"point","display":"313","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"313"},{"value":281,"low":277,"high":281,"kind":"range","display":"277–281","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"277–281"}]},{"analyteId":"ph","name":"pH","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"A measure of how acidic or basic the water is.","whyItMatters":"Regulated only as a secondary standard; very low or high pH can corrode pipes or affect taste.","measured":{"value":8.7,"low":6.8,"high":8.7,"kind":"range","display":"6.8–8.7","units":null,"statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"6.8–8.7¹²"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"","average":null,"range":{"low":6.8,"high":8.7,"display":"6.8–8.7"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"","average":null,"range":{"low":8.1,"high":8.1,"display":"8.1–8.1"},"ratio":null}],"measurements":[{"value":8.1,"low":null,"high":null,"kind":"point","display":"8.1","units":null,"statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"8.1"},{"value":8.7,"low":6.8,"high":8.7,"kind":"range","display":"6.8–8.7","units":null,"statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"6.8–8.7¹²"},{"value":7.25,"low":null,"high":null,"kind":"point","display":"7.25","units":null,"statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"7.25¹²"},{"value":8.1,"low":8.1,"high":8.1,"kind":"range","display":"8.1–8.1","units":null,"statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"8.1–8.1"}]},{"analyteId":"toc","name":"TOC","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"Total organic carbon — a measure of organic material dissolved in the water.","whyItMatters":"Not harmful itself, but it is the raw material that forms disinfection byproducts; removal is a treatment requirement.","measured":{"value":2.6,"low":1.7,"high":2.6,"kind":"range","display":"1.7–2.6","units":null,"statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"1.7–2.6"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":2.4,"low":null,"high":null,"kind":"point","display":"2.4","units":null,"statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"2.4"},{"value":2.6,"low":1.7,"high":2.6,"kind":"range","display":"1.7–2.6","units":null,"statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"1.7–2.6"}]}]},{"family":"radionuclide","familyLabel":"Radionuclides","contaminants":[{"analyteId":"combined_radium","name":"Combined Radium","family":"radionuclide","familyLabel":"Radionuclides","casrn":null,"whatItIs":"Combined radium-226 and radium-228 — naturally occurring radioactive elements.","whyItMatters":"Long-term exposure above the federal limit increases the risk of bone cancer.","measured":{"value":1,"low":0,"high":1,"kind":"range","display":"0–1","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"ND–1"},"federalStandard":{"type":"MCL","value":5,"units":"pCi/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"},{"value":1,"low":0,"high":1,"kind":"range","display":"0–1","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND–1"}]},{"analyteId":"gross_alpha","name":"Gross Alpha","family":"radionuclide","familyLabel":"Radionuclides","casrn":null,"whatItIs":"Gross alpha particle activity — a combined measure of alpha-emitting radioactive substances.","whyItMatters":"Long-term exposure above the federal limit increases cancer risk.","measured":{"value":7.5,"low":2.4,"high":7.5,"kind":"range","display":"2.4–7.5","units":"pCi/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"2.4–7.5⁴"},"federalStandard":{"type":"MCL","value":15,"units":"pCi/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"pCi/L","average":null,"range":{"low":2.4,"high":7.5,"display":"2.4–7.5"},"ratio":0.5},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"pCi/L","average":null,"range":{"low":4,"high":7,"display":"4–7"},"ratio":0.4666666666666667}],"measurements":[{"value":6,"low":null,"high":null,"kind":"point","display":"6","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"6⁵"},{"value":7,"low":4,"high":7,"kind":"range","display":"4–7","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"4–7⁵"},{"value":3.9,"low":null,"high":null,"kind":"point","display":"3.9","units":"pCi/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"3.9⁴"},{"value":7.5,"low":2.4,"high":7.5,"kind":"range","display":"2.4–7.5","units":"pCi/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"2.4–7.5⁴"}]},{"analyteId":"gross_beta","name":"Gross Beta Particle Activity","family":"radionuclide","familyLabel":"Radionuclides","casrn":null,"whatItIs":"Gross beta particle activity — a combined measure of beta-emitting radioactive substances.","whyItMatters":"Long-term exposure above the federal screening level increases cancer risk.","measured":{"value":6,"low":4,"high":6,"kind":"range","display":"4–6","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"4–6⁷"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":5,"low":null,"high":null,"kind":"point","display":"5","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"5⁷"},{"value":6,"low":4,"high":6,"kind":"range","display":"4–6","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"4–6⁷"}]},{"analyteId":"uranium","name":"Uranium","family":"radionuclide","familyLabel":"Radionuclides","casrn":"7440-61-1","whatItIs":"A naturally occurring radioactive metal from erosion of natural deposits.","whyItMatters":"Long-term exposure above the federal limit can damage the kidneys and increase cancer risk.","measured":{"value":12,"low":1.6,"high":12,"kind":"range","display":"1.6–12","units":"pCi/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"1.6–12⁴"},"federalStandard":{"type":"MCL","value":20,"units":"pCi/L","enforceable":true},"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"pCi/L","average":null,"range":{"low":1.6,"high":12,"display":"1.6–12"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"pCi/L","average":null,"range":{"low":1,"high":3,"display":"1–3"},"ratio":null}],"measurements":[{"value":4.3,"low":null,"high":null,"kind":"point","display":"4.3","units":"pCi/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"4.3⁴"},{"value":3,"low":1,"high":3,"kind":"range","display":"1–3","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"1–3⁵,⁷"},{"value":2,"low":null,"high":null,"kind":"point","display":"2","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"2⁵,⁷"},{"value":12,"low":1.6,"high":12,"kind":"range","display":"1.6–12","units":"pCi/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"1.6–12⁴"}]}]}],"contaminants":[{"analyteId":"bromate","name":"Bromate","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":"15541-45-4","whatItIs":"A disinfection byproduct formed when bromide-containing water is treated with ozone.","whyItMatters":"Classified as a probable human carcinogen; the EPA sets a strict maximum contaminant level.","measured":{"value":7.6,"low":0,"high":7.6,"kind":"range","display":"0–7.6","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"ND–7.6"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"},{"value":7.6,"low":0,"high":7.6,"kind":"range","display":"0–7.6","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND–7.6"}]},{"analyteId":"chlorate","name":"Chlorate","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":"14866-68-3","whatItIs":"A byproduct that can form during disinfection, especially when hypochlorite solutions degrade.","whyItMatters":"Has no enforceable federal limit but is on the EPA contaminant candidate list; high levels can affect the thyroid.","measured":{"value":88,"low":null,"high":null,"kind":"point","display":"88","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"88⁵"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":88,"low":null,"high":null,"kind":"point","display":"88","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"88⁵"},{"value":88,"low":88,"high":88,"kind":"range","display":"88–88","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"88–88⁵"}]},{"analyteId":"haa5","name":"HAA5","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":null,"whatItIs":"Haloacetic acids — a group of five disinfection byproducts formed when disinfectants react with organic matter.","whyItMatters":"Long-term exposure above the federal limit is associated with an increased cancer risk.","measured":{"value":19,"low":5.9,"high":19,"kind":"range","display":"5.9–19","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"5.9–19⁸"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":5.9,"high":19,"display":"5.9–19"},"ratio":0.31666666666666665},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":{"low":1.5,"high":14,"display":"1.5–14"},"ratio":0.23333333333333334}],"measurements":[{"value":9.8,"low":null,"high":null,"kind":"point","display":"9.8","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"9.8⁹,¹⁰"},{"value":19,"low":5.9,"high":19,"kind":"range","display":"5.9–19","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"5.9–19⁸"},{"value":14,"low":1.5,"high":14,"kind":"range","display":"1.5–14","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"1.5–14⁹,¹⁰"},{"value":12.4,"low":null,"high":null,"kind":"point","display":"12.4","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"12.4⁸"}]},{"analyteId":"ndma","name":"NDMA","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":"62-75-9","whatItIs":null,"whyItMatters":null,"measured":{"value":3.3,"low":0,"high":3.3,"kind":"range","display":"0–3.3","units":"ng/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"ND–3.3⁵"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":3.3,"low":0,"high":3.3,"kind":"range","display":"0–3.3","units":"ng/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND–3.3⁵"}]},{"analyteId":"tthm","name":"TTHM","family":"disinfection_byproduct","familyLabel":"Disinfection byproducts","casrn":null,"whatItIs":"Total trihalomethanes — a group of four chemicals (including chloroform) formed when chlorine reacts with natural organic matter.","whyItMatters":"Long-term exposure above the federal limit is linked to liver, kidney, and central-nervous-system effects and increased cancer risk.","measured":{"value":69,"low":26,"high":69,"kind":"range","display":"26–69","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"26.0–69.0⁸"},"federalStandard":null,"status":{"key":"approaching","label":"Approaching the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":26,"high":69,"display":"26–69"},"ratio":0.8625},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":{"low":11,"high":42,"display":"11–42"},"ratio":0.525}],"measurements":[{"value":46.5,"low":null,"high":null,"kind":"point","display":"46.5","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"46.5⁸"},{"value":34,"low":null,"high":null,"kind":"point","display":"34","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"34"},{"value":69,"low":26,"high":69,"kind":"range","display":"26–69","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"26.0–69.0⁸"},{"value":42,"low":11,"high":42,"kind":"range","display":"11–42","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"11–42"}]},{"analyteId":"fluoride","name":"Fluoride","family":"inorganic","familyLabel":"Inorganic chemicals","casrn":"16984-48-8","whatItIs":"A mineral often added to drinking water to help prevent tooth decay.","whyItMatters":"Beneficial at low levels, but long-term exposure above the federal limit can cause bone disease and tooth mottling.","measured":{"value":0.9,"low":0.4,"high":0.9,"kind":"range","display":"0.4–0.9","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"0.4–0.9³"},"federalStandard":{"type":"MCL","value":4,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":0.4,"high":0.9,"display":"0.4–0.9"},"ratio":0.225},{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":0.27,"high":0.49,"display":"0.27–0.49"},"ratio":0.1225}],"measurements":[{"value":0.7,"low":null,"high":null,"kind":"point","display":"0.7","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.7"},{"value":0.44,"low":null,"high":null,"kind":"point","display":"0.44","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.44²"},{"value":0.49,"low":0.27,"high":0.49,"kind":"range","display":"0.27–0.49","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.27–0.49"},{"value":0.9,"low":0.4,"high":0.9,"kind":"range","display":"0.4–0.9","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.4–0.9³"}]},{"analyteId":"nitrate","name":"Nitrate","family":"inorganic","familyLabel":"Inorganic chemicals","casrn":"14797-55-8","whatItIs":"A compound from fertilizer runoff, septic systems, and erosion of natural deposits.","whyItMatters":"Levels above the federal limit can cause 'blue baby syndrome,' a serious oxygen-transport condition in infants.","measured":{"value":33.1,"low":16.1,"high":33.1,"kind":"range","display":"16.1–33.1","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"16.1–33.1¹²"},"federalStandard":{"type":"MCL","value":10,"units":"mg/L","enforceable":true},"status":{"key":"over","label":"At or above the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":16.1,"high":33.1,"display":"16.1–33.1"},"ratio":3.31},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":22.6,"low":null,"high":null,"kind":"point","display":"22.6","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"22.6¹²"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"},{"value":33.1,"low":16.1,"high":33.1,"kind":"range","display":"16.1–33.1","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"16.1–33.1¹²"}]},{"analyteId":"aluminum","name":"Aluminum","family":"metal","familyLabel":"Metals","casrn":"7429-90-5","whatItIs":"A common element sometimes used as a treatment coagulant.","whyItMatters":"Regulated only as a secondary (cosmetic) standard; high levels can discolor water.","measured":{"value":0.24,"low":0.052,"high":0.24,"kind":"range","display":"0.052–0.24","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"0.052–0.24¹"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":0.052,"high":0.24,"display":"0.052–0.24"},"ratio":null},{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":null,"ratio":null}],"measurements":[{"value":0.156,"low":null,"high":null,"kind":"point","display":"0.156","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.156¹"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND"},{"value":0.24,"low":0.052,"high":0.24,"kind":"range","display":"0.052–0.24","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.052–0.24¹"}]},{"analyteId":"arsenic","name":"Arsenic","family":"metal","familyLabel":"Metals","casrn":"7440-38-2","whatItIs":"A naturally occurring element that also enters water from industry and agriculture.","whyItMatters":"A known human carcinogen; long-term exposure is linked to skin, bladder, and lung cancer.","measured":{"value":5.1,"low":0,"high":5.1,"kind":"range","display":"0–5.1","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"ND–5.10"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":5.1,"low":0,"high":5.1,"kind":"range","display":"0–5.1","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND–5.10"},{"value":0.09,"low":null,"high":null,"kind":"point","display":"0.09","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.09"}]},{"analyteId":"barium","name":"Barium","family":"metal","familyLabel":"Metals","casrn":"7440-39-3","whatItIs":"A metal from erosion of natural deposits and industrial discharge.","whyItMatters":"Long-term exposure above the federal limit can raise blood pressure.","measured":{"value":0.13,"low":0,"high":0.13,"kind":"range","display":"0–0.13","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"ND–0.13"},"federalStandard":{"type":"MCL","value":2,"units":"mg/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":0,"high":0.13,"display":"0–0.13"},"ratio":0.065},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":0.107,"high":0.107,"display":"0.107–0.107"},"ratio":0.0535}],"measurements":[{"value":0.107,"low":0.107,"high":0.107,"kind":"range","display":"0.107–0.107","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.107–0.107"},{"value":0.107,"low":null,"high":null,"kind":"point","display":"0.107","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"0.107"},{"value":0.13,"low":0,"high":0.13,"kind":"range","display":"0–0.13","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND–0.13"},{"value":0.1,"low":null,"high":null,"kind":"point","display":"0.1","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.1"}]},{"analyteId":"boron","name":"Boron","family":"metal","familyLabel":"Metals","casrn":"7440-42-8","whatItIs":"A naturally occurring element from rock and soil.","whyItMatters":"No enforceable federal limit; the EPA has issued a health advisory level.","measured":{"value":140,"low":0,"high":140,"kind":"range","display":"0–140","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"ND–140"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":0,"high":140,"display":"0–140"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":{"low":140,"high":140,"display":"140–140"},"ratio":null}],"measurements":[{"value":140,"low":0,"high":140,"kind":"range","display":"0–140","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND–140"},{"value":140,"low":null,"high":null,"kind":"point","display":"140","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"140"},{"value":20,"low":null,"high":null,"kind":"point","display":"20","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"20"},{"value":140,"low":140,"high":140,"kind":"range","display":"140–140","units":"ug/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"140–140"}]},{"analyteId":"calcium","name":"Calcium","family":"metal","familyLabel":"Metals","casrn":"7440-70-2","whatItIs":"A naturally occurring mineral that contributes to water hardness.","whyItMatters":"Not federally regulated for health; affects scaling and taste.","measured":{"value":96,"low":35,"high":96,"kind":"range","display":"35–96","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"35–96"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":35,"high":96,"display":"35–96"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":68,"high":71,"display":"68–71"},"ratio":null}],"measurements":[{"value":71,"low":68,"high":71,"kind":"range","display":"68–71","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"68–71"},{"value":70,"low":null,"high":null,"kind":"point","display":"70","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"70"},{"value":81,"low":null,"high":null,"kind":"point","display":"81","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"81"},{"value":96,"low":35,"high":96,"kind":"range","display":"35–96","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"35–96"}]},{"analyteId":"chromium_hex","name":"Chromium, Hexavalent","family":"metal","familyLabel":"Metals","casrn":"18540-29-9","whatItIs":"Hexavalent chromium ('chromium-6') — the more toxic form of chromium.","whyItMatters":"A known carcinogen by inhalation; regulated nationally only within the total-chromium limit, with stricter limits in some states.","measured":{"value":2,"low":0.32,"high":2,"kind":"range","display":"0.32–2","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"0.32–2.0"},"federalStandard":{"type":"PHG","value":0.02,"units":"ug/L","enforceable":false},"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":0.32,"high":2,"display":"0.32–2"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":null,"ratio":null}],"measurements":[{"value":0.67,"low":null,"high":null,"kind":"point","display":"0.67","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.67"},{"value":2,"low":0.32,"high":2,"kind":"range","display":"0.32–2","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.32–2.0"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"}]},{"analyteId":"copper","name":"Copper","family":"metal","familyLabel":"Metals","casrn":"7440-50-8","whatItIs":"A metal that enters water from corroding household plumbing.","whyItMatters":"Short-term exposure causes stomach distress; long-term exposure can damage the liver and kidneys.","measured":{"value":315,"low":null,"high":null,"kind":"point","display":"315","units":"ug/L","statisticType":"p90","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"315"},"federalStandard":{"type":"AL","value":1300,"units":"ug/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":315,"low":null,"high":null,"kind":"point","display":"315","units":"ug/L","statisticType":"p90","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"315"}]},{"analyteId":"lead","name":"Lead","family":"metal","familyLabel":"Metals","casrn":"7439-92-1","whatItIs":"A toxic metal that leaches into water from old service lines, solder, and plumbing fixtures.","whyItMatters":"There is no safe level of lead; it harms brain development in children and raises blood pressure in adults. The EPA sets an action level, not a health goal above zero.","measured":{"value":2.1,"low":null,"high":null,"kind":"point","display":"2.1","units":"ug/L","statisticType":"p90","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"2.1"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":2.1,"low":null,"high":null,"kind":"point","display":"2.1","units":"ug/L","statisticType":"p90","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"2.1"}]},{"analyteId":"magnesium","name":"Magnesium","family":"metal","familyLabel":"Metals","casrn":"7439-95-4","whatItIs":"A naturally occurring mineral that contributes to water hardness.","whyItMatters":"Not federally regulated for health; affects scaling and taste.","measured":{"value":31,"low":11,"high":31,"kind":"range","display":"11–31","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"11–31"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":11,"high":31,"display":"11–31"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":25,"high":26,"display":"25–26"},"ratio":null}],"measurements":[{"value":31,"low":11,"high":31,"kind":"range","display":"11–31","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"11–31"},{"value":27,"low":null,"high":null,"kind":"point","display":"27","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"27"},{"value":26,"low":null,"high":null,"kind":"point","display":"26","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"26"},{"value":26,"low":25,"high":26,"kind":"range","display":"25–26","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"25–26"}]},{"analyteId":"potassium","name":"Potassium","family":"metal","familyLabel":"Metals","casrn":"7440-09-7","whatItIs":"A naturally occurring mineral from rock and soil.","whyItMatters":"Not federally regulated for health.","measured":{"value":4.8,"low":4.5,"high":4.8,"kind":"range","display":"4.5–4.8","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"4.5–4.8"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":4.5,"high":4.8,"display":"4.5–4.8"},"ratio":null},{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":2.6,"high":3.9,"display":"2.6–3.9"},"ratio":null}],"measurements":[{"value":3.9,"low":2.6,"high":3.9,"kind":"range","display":"2.6–3.9","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"2.6–3.9"},{"value":3.3,"low":null,"high":null,"kind":"point","display":"3.3","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"3.3"},{"value":4.8,"low":4.5,"high":4.8,"kind":"range","display":"4.5–4.8","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"4.5–4.8"},{"value":4.6,"low":null,"high":null,"kind":"point","display":"4.6","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"4.6"}]},{"analyteId":"sodium","name":"Sodium","family":"metal","familyLabel":"Metals","casrn":"7440-23-5","whatItIs":"A naturally occurring salt component.","whyItMatters":"Not federally regulated for health; relevant for people on sodium-restricted diets.","measured":{"value":103,"low":98,"high":103,"kind":"range","display":"98–103","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"98–103"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":98,"high":103,"display":"98–103"},"ratio":null},{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":17,"high":41,"display":"17–41"},"ratio":null}],"measurements":[{"value":35,"low":null,"high":null,"kind":"point","display":"35","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"35"},{"value":100,"low":null,"high":null,"kind":"point","display":"100","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"100"},{"value":41,"low":17,"high":41,"kind":"range","display":"17–41","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"17–41"},{"value":103,"low":98,"high":103,"kind":"range","display":"98–103","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"98–103"}]},{"analyteId":"vanadium","name":"Vanadium","family":"metal","familyLabel":"Metals","casrn":"7440-62-2","whatItIs":null,"whyItMatters":null,"measured":{"value":4.8,"low":0,"high":4.8,"kind":"range","display":"0–4.8","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"ND–4.8"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":0,"high":4.8,"display":"0–4.8"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":null,"ratio":null}],"measurements":[{"value":4,"low":null,"high":null,"kind":"point","display":"4","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"4"},{"value":4.8,"low":0,"high":4.8,"kind":"range","display":"0–4.8","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND–4.8"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"}]},{"analyteId":"pce","name":"Pce","family":"other","familyLabel":"Other","casrn":null,"whatItIs":null,"whyItMatters":null,"measured":{"value":0.45,"low":0,"high":0.45,"kind":"range","display":"0–0.45","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"ND–0.45¹²"},"federalStandard":null,"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"ug/L","average":null,"range":{"low":0,"high":0.45,"display":"0–0.45"},"ratio":0.09000000000000001},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"ug/L","average":null,"range":null,"ratio":0}],"measurements":[{"value":0.45,"low":0,"high":0.45,"kind":"range","display":"0–0.45","units":"ug/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"ND–0.45¹²"},{"value":0.29,"low":null,"high":null,"kind":"point","display":"0.29","units":"ug/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"0.29¹²"},{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"ug/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"}]},{"analyteId":"alkalinity","name":"Alkalinity","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"A measure of the water's capacity to neutralize acids.","whyItMatters":"Not federally regulated for health; relevant to corrosion control and treatment.","measured":{"value":180,"low":110,"high":180,"kind":"range","display":"110–180","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"110–180"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":110,"high":180,"display":"110–180"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":126,"high":128,"display":"126–128"},"ratio":null}],"measurements":[{"value":127,"low":null,"high":null,"kind":"point","display":"127","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"127"},{"value":128,"low":126,"high":128,"kind":"range","display":"126–128","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"126–128"},{"value":180,"low":110,"high":180,"kind":"range","display":"110–180","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"110–180"},{"value":151,"low":null,"high":null,"kind":"point","display":"151","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"151"}]},{"analyteId":"bicarbonate","name":"Bicarbonate","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":"71-52-3","whatItIs":null,"whyItMatters":null,"measured":{"value":180,"low":110,"high":180,"kind":"range","display":"110–180","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"110–180"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":180,"low":110,"high":180,"kind":"range","display":"110–180","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"110–180"},{"value":151,"low":null,"high":null,"kind":"point","display":"151","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"151"}]},{"analyteId":"hardness","name":"Hardness","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"A measure of dissolved calcium and magnesium minerals.","whyItMatters":"Not federally regulated for health; affects scaling, soap use, and taste.","measured":{"value":360,"low":130,"high":360,"kind":"range","display":"130–360","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"130–360"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"mg/L","average":null,"range":{"low":130,"high":360,"display":"130–360"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"mg/L","average":null,"range":{"low":277,"high":281,"display":"277–281"},"ratio":null}],"measurements":[{"value":279,"low":null,"high":null,"kind":"point","display":"279","units":"mg/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"279"},{"value":360,"low":130,"high":360,"kind":"range","display":"130–360","units":"mg/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"130–360"},{"value":313,"low":null,"high":null,"kind":"point","display":"313","units":"mg/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"313"},{"value":281,"low":277,"high":281,"kind":"range","display":"277–281","units":"mg/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"277–281"}]},{"analyteId":"ph","name":"pH","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"A measure of how acidic or basic the water is.","whyItMatters":"Regulated only as a secondary standard; very low or high pH can corrode pipes or affect taste.","measured":{"value":8.7,"low":6.8,"high":8.7,"kind":"range","display":"6.8–8.7","units":null,"statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"6.8–8.7¹²"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"","average":null,"range":{"low":6.8,"high":8.7,"display":"6.8–8.7"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"","average":null,"range":{"low":8.1,"high":8.1,"display":"8.1–8.1"},"ratio":null}],"measurements":[{"value":8.1,"low":null,"high":null,"kind":"point","display":"8.1","units":null,"statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"8.1"},{"value":8.7,"low":6.8,"high":8.7,"kind":"range","display":"6.8–8.7","units":null,"statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"6.8–8.7¹²"},{"value":7.25,"low":null,"high":null,"kind":"point","display":"7.25","units":null,"statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"7.25¹²"},{"value":8.1,"low":8.1,"high":8.1,"kind":"range","display":"8.1–8.1","units":null,"statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"8.1–8.1"}]},{"analyteId":"toc","name":"TOC","family":"physical_aggregate","familyLabel":"Physical & aggregate","casrn":null,"whatItIs":"Total organic carbon — a measure of organic material dissolved in the water.","whyItMatters":"Not harmful itself, but it is the raw material that forms disinfection byproducts; removal is a treatment requirement.","measured":{"value":2.6,"low":1.7,"high":2.6,"kind":"range","display":"1.7–2.6","units":null,"statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"1.7–2.6"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":2.4,"low":null,"high":null,"kind":"point","display":"2.4","units":null,"statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"2.4"},{"value":2.6,"low":1.7,"high":2.6,"kind":"range","display":"1.7–2.6","units":null,"statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"1.7–2.6"}]},{"analyteId":"combined_radium","name":"Combined Radium","family":"radionuclide","familyLabel":"Radionuclides","casrn":null,"whatItIs":"Combined radium-226 and radium-228 — naturally occurring radioactive elements.","whyItMatters":"Long-term exposure above the federal limit increases the risk of bone cancer.","measured":{"value":1,"low":0,"high":1,"kind":"range","display":"0–1","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"ND–1"},"federalStandard":{"type":"MCL","value":5,"units":"pCi/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[],"measurements":[{"value":0,"low":null,"high":null,"kind":"non_detect","display":"Not detected","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND"},{"value":1,"low":0,"high":1,"kind":"range","display":"0–1","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"ND–1"}]},{"analyteId":"gross_alpha","name":"Gross Alpha","family":"radionuclide","familyLabel":"Radionuclides","casrn":null,"whatItIs":"Gross alpha particle activity — a combined measure of alpha-emitting radioactive substances.","whyItMatters":"Long-term exposure above the federal limit increases cancer risk.","measured":{"value":7.5,"low":2.4,"high":7.5,"kind":"range","display":"2.4–7.5","units":"pCi/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"2.4–7.5⁴"},"federalStandard":{"type":"MCL","value":15,"units":"pCi/L","enforceable":true},"status":{"key":"under","label":"Within the limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"pCi/L","average":null,"range":{"low":2.4,"high":7.5,"display":"2.4–7.5"},"ratio":0.5},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"pCi/L","average":null,"range":{"low":4,"high":7,"display":"4–7"},"ratio":0.4666666666666667}],"measurements":[{"value":6,"low":null,"high":null,"kind":"point","display":"6","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"6⁵"},{"value":7,"low":4,"high":7,"kind":"range","display":"4–7","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"4–7⁵"},{"value":3.9,"low":null,"high":null,"kind":"point","display":"3.9","units":"pCi/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"3.9⁴"},{"value":7.5,"low":2.4,"high":7.5,"kind":"range","display":"2.4–7.5","units":"pCi/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"2.4–7.5⁴"}]},{"analyteId":"gross_beta","name":"Gross Beta Particle Activity","family":"radionuclide","familyLabel":"Radionuclides","casrn":null,"whatItIs":"Gross beta particle activity — a combined measure of beta-emitting radioactive substances.","whyItMatters":"Long-term exposure above the federal screening level increases cancer risk.","measured":{"value":6,"low":4,"high":6,"kind":"range","display":"4–6","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","censored":false,"detectionLimit":null,"rawVerbatim":"4–6⁷"},"federalStandard":null,"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[],"measurements":[{"value":5,"low":null,"high":null,"kind":"point","display":"5","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"5⁷"},{"value":6,"low":4,"high":6,"kind":"range","display":"4–6","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"4–6⁷"}]},{"analyteId":"uranium","name":"Uranium","family":"radionuclide","familyLabel":"Radionuclides","casrn":"7440-61-1","whatItIs":"A naturally occurring radioactive metal from erosion of natural deposits.","whyItMatters":"Long-term exposure above the federal limit can damage the kidneys and increase cancer risk.","measured":{"value":12,"low":1.6,"high":12,"kind":"range","display":"1.6–12","units":"pCi/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","censored":false,"detectionLimit":null,"rawVerbatim":"1.6–12⁴"},"federalStandard":{"type":"MCL","value":20,"units":"pCi/L","enforceable":true},"status":{"key":"detected","label":"Detected — no federal limit"},"breakdowns":[{"context":"zone:Crescenta Valley Water District","label":"Crescenta Valley Water District","kind":"zone","units":"pCi/L","average":null,"range":{"low":1.6,"high":12,"display":"1.6–12"},"ratio":null},{"context":"plant:Metropolitan Water District's F. E. Weymouth Plant","label":"Metropolitan Water District's F. E. Weymouth Plant","kind":"plant","units":"pCi/L","average":null,"range":{"low":1,"high":3,"display":"1–3"},"ratio":null}],"measurements":[{"value":4.3,"low":null,"high":null,"kind":"point","display":"4.3","units":"pCi/L","statisticType":"reported_level","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"4.3⁴"},{"value":3,"low":1,"high":3,"kind":"range","display":"1–3","units":"pCi/L","statisticType":"range","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"1–3⁵,⁷"},{"value":2,"low":null,"high":null,"kind":"point","display":"2","units":"pCi/L","statisticType":"reported_level","samplingContext":"plant:Metropolitan Water District's F. E. Weymouth Plant","rawVerbatim":"2⁵,⁷"},{"value":12,"low":1.6,"high":12,"kind":"range","display":"1.6–12","units":"pCi/L","statisticType":"range","samplingContext":"zone:Crescenta Valley Water District","rawVerbatim":"1.6–12⁴"}]}]}}