Drinking water quality · 2022

· Verified

· PWSID CA1910163

What's in Valencia Heights Water Co. — West Covina, Ca, CA tap water

D
Water quality score
60/ 100Concern

2 contaminants in Valencia Heights Water Co. — West Covina, Ca, CA's water sat at or above a federal limit, led by Bromate at 1.2x the limit.

  • !2 contaminants at or above a federal limit — worst is Bromate at 1.2x
  • !1 contaminant within 20% of a limit
  • !13 of 27 core regulated contaminants reported — 14 never appear in this report
  • ✓No open federal violations
+How this score is calculated

Every system starts at 100. Points come off for measured levels, for the federal violation record, and for how much of the core regulated set the utility actually reported. All three inputs are the utility's own published numbers and EPA's own records.

  • −27  contaminants at or above a federal limit
  • −4  contaminants within 20% of a limit
  • −0  open health-based violations
  • −0  open monitoring / reporting violations
  • −0  health-based violations resolved in the last 5 years
  • −9  core regulated contaminants never reported (13/27)

A 90–100 · B 80–89 · C 70–79 · D 60–69 · F below 60. A system reporting under a third of the core set is capped at C however clean its numbers look — a short report is not a clean bill of health.

Full grading methodology, constant for constant →

What to worry about

  • Bromate1.2× the federal limit
    0–12 ug/L · limit 10 ug/L

    Classified as a probable human carcinogen; the EPA sets a strict maximum contaminant level.

    Higher than 95% of CA systems that report it · higher than 95% of U.S. systems

  • PFOS1.0× the federal limit
    4 ng/L · limit 4 ng/L

    Linked to cancer, thyroid disease, and immune effects; the EPA set an enforceable limit of 4 parts per trillion.

    Higher than 40% of CA systems that report it · higher than 50% of U.S. systems

  • Chlorine95% of the federal limit
    0.3–3.8 mg/L · limit 4 mg/L

    Effective and necessary, but high residual levels can cause taste and odor issues; the EPA caps the residual disinfectant level.

    Higher than 95% of CA systems that report it · higher than 95% of U.S. systems

+27 contaminants were measured and came in below the limitShow all
ContaminantMeasured
Nitrate0.71–6 mg/L
Turbidity0.28–0.5 NTU
Copper0.63 mg/L
TTHM29 ug/L
Arsenic0–3.1 ug/L
Perfluorohexanesulfonic acid3 ng/L
HAA54.8–15 ug/L
Gross Alpha3.3 pCi/L
Fluoride0.6–0.8 mg/L
Barium0–0.12 mg/L
Perchlorate0–3.9 ug/L
Chloride93–110 mg/L
Sulfate230–280 mg/L
Aluminum120 ug/L
Boron0.12–0.14 mg/L
LeadNot detected ug/L
Manganese0–29 ug/L
Sodium68–70 mg/L
Vanadium8–9.7 ug/L
Perfluorobutanesulfonic acid3 ng/L
Color4–5
Hardness520–610 mg/L
Odor2
Specific Conductance1300 uS/cm
Total Dissolved Solids750–920 mg/L
Gross Beta Particle Activity0–6 pCi/L
Uranium2.7–9.7 pCi/L

What this report doesn't tell you

14 of the 27 contaminants a community water system normally reports do not appear anywhere in Valencia Heights Water Co. — West Covina, Ca, CA's data. Absent is not the same as absent-from-the-water — it means nobody published a number.

Coliform bacteriaChromiumSeleniumAntimonyCadmiumMercuryThalliumBerylliumCyanideRadiumAtrazine / simazineTetrachloroethylene (PCE)Trichloroethylene (TCE)Benzene
Browse the mapFull source report ↗
+Full detail: PFAS testing, water source, historical monitoring, and the federal violation record

Compliance history

Federal Safe Drinking Water Act violation & enforcement records (EPA SDWIS). A violation is a regulatory determination by the state or EPA — separate from the measured levels above.

  • Maximum contaminant level exceededHealth-based
    1 violation on record · most recent Feb 1996
    resolved
  • Treatment technique violationHealth-based
    1 violation on record · most recent May 1993
    resolved

Source: EPA SDWIS / ECHO. View the full federal record on EPA ECHO ↗

Source: Valencia Heights Water Co. — West Covina, Ca, CA's 2022 Consumer Confidence Report — the annual drinking-water report every U.S. utility is required to publish. The numbers on this page are the utility's own. A water-quality report covers an entire service area, not a single address.
The grade at the top of this page is computed, not editorial. See exactly how we grade water systems — every deduction, every ceiling, every threshold.

More water systems in CA