Drinking water quality · 2022
· Verified
· PWSID CA2710702
What's in Fort Hunter Liggett — Fort Hunter Liggett, Ca, CA tap water
1 contaminant in Fort Hunter Liggett — Fort Hunter Liggett, Ca, CA's water sat at or above a federal limit, led by Turbidity at 11.5x the limit.
- !1 contaminant at or above a federal limit — worst is Turbidity at 11.5x
- !11 of 27 core regulated contaminants reported — 16 never appear in this report
- ✓No open federal violations
+How this score is calculated
Every system starts at 100. Points come off for measured levels, for the federal violation record, and for how much of the core regulated set the utility actually reported. All three inputs are the utility's own published numbers and EPA's own records.
- −36 contaminants at or above a federal limit
- −0 contaminants within 20% of a limit
- −0 open health-based violations
- −0 open monitoring / reporting violations
- −0 health-based violations resolved in the last 5 years
- −13 core regulated contaminants never reported (11/27)
A 90–100 · B 80–89 · C 70–79 · D 60–69 · F below 60. A system reporting under a third of the core set is capped at C however clean its numbers look — a short report is not a clean bill of health.
Full grading methodology, constant for constant →What to worry about
- Turbidity11.5× the federal limit11.48 NTU · limit 1 NTU
High turbidity can shelter microbes from disinfection; the EPA enforces it through a treatment-technique standard.
Higher than 95% of CA systems that report it · higher than 90% of U.S. systems
+15 contaminants were measured and came in below the limitShow all
| Contaminant | Measured | Federal limit |
|---|---|---|
| Lead | 0.0074 mg/L | 0.015 mg/L |
| Copper | 0.54 mg/L | 1.3 mg/L |
| Combined Radium | 1.61 pCi/L | 5 pCi/L |
| Nitrate | 2.06 mg/L | 10 mg/L |
| TTHM | 12 ug/L | 80 ug/L |
| Chlorine | 0.46 mg/L | 4 mg/L |
| Gross Alpha | 1.33 pCi/L | 15 pCi/L |
| HAA5 | 3.4 ug/L | 60 ug/L |
| Fluoride | 0.15 mg/L | 4 mg/L |
| Chloride | 42 mg/L | — |
| Sulfate | 64 mg/L | — |
| Arsenic | Not detected ug/L | 10 ug/L |
| Vanadium | 6.5 ug/L | — |
| Specific Conductance | 560 | — |
| Total Dissolved Solids | 340 mg/L | — |
What this report doesn't tell you
16 of the 27 contaminants a community water system normally reports do not appear anywhere in Fort Hunter Liggett — Fort Hunter Liggett, Ca, CA's data. Absent is not the same as absent-from-the-water — it means nobody published a number.
+Full detail: PFAS testing, water source, historical monitoring, and the federal violation record
Compliance history
Federal Safe Drinking Water Act violation & enforcement records (EPA SDWIS). A violation is a regulatory determination by the state or EPA — separate from the measured levels above.