Drinking water quality · 2025

· Verified

What's in Bakersfield, City of, CA tap water

113 contaminants were measured in the Bakersfield, City of, CA water system's 2025 annual report. Each is shown below against its federal limit 2 sit at or above that limit.

Reporting year
2025
Contaminants measured
113
Over federal limit
2
Approaching the limit
1
Worst contaminant
1,2,3-TCP
8.0× the limit
Service area
CA
state-level CCR
Source
Utility CCR

PFAS — EPA UCMR5 (2023–2025)

1 PFAS compound above EPA limits in Bakersfield, City of, CA

About this data

The EPA finalized the first-ever federal drinking-water limits for six PFAS compounds in April 2024. These numbers come straight from EPA's UCMR5 lab dataset — every U.S. system serving more than 3,300 people tested every PFAS sample at an entry point to its distribution system. PFAS not listed below were either tested and not detected, or not yet sampled.

PFOS (Perfluorooctane sulfonic acid)

● Over EPA limit (1.9×)
Measured 7.6 ng/LEPA limit 4 ng/LSample year 2025Samples 3 detect / 42

below national p90 (19.900000000000006 ng/L across detecting U.S. systems)

PFNA (Perfluorononanoic acid)

● Below limit
Measured 4.7 ng/LEPA limit 10 ng/LSample year 2025Samples 1 detect / 42

below national p90 (25.08 ng/L across detecting U.S. systems)

PFHxS (Perfluorohexane sulfonic acid)

● Below limit
Measured 4.2 ng/LEPA limit 10 ng/LSample year 2025Samples 1 detect / 42

below national p90 (12.049999999999997 ng/L across detecting U.S. systems)

Lithium

● Detected (no federal limit)
Measured 14.8 mg/LSample year 2024Samples 2 detect / 39

below national p90 (76.59999999999991 mg/L across detecting U.S. systems)

PWSID CA1510031 · Source: EPA UCMR5. Limits per EPA's April 2024 PFAS National Primary Drinking Water Regulation. PFAS values reported in nanograms per liter (ng/L) — note that 1 ng/L = 1 part per trillion.

Where your water comes from · EPA SDWIS

Bakersfield, City of, CA's drinking water comes from ground water, drawn from 63 sources.

Source

63ground water
  • WELL CBK 36-01 - BEFORE_GAC-TCP
  • WELL CBK 31-01 - BEFORE GAC
  • WELL CBK 20-01 - RAW
  • WELL CBK 21-01 - BEFORE_GAC-TCP
  • + 59 more

Treatment

68treatment plants
  • WELL CBK 18-01 - CL2
  • WELL CBK 19-01 - AFTER_GAC-TCP
  • WELL CBK 20-01 - CL2
  • + 65 more

Distribution

0storage units

Also buys water from CWS - NORTH GARDEN, KERN COUNTY WATER AGENCY.

Historical readings · EPA Six-Year Review (2012–2019)

5 contaminants historically over EPA limits in Bakersfield, City of, CA

About this data

Every U.S. public water system reports compliance-monitoring data to EPA. The Six-Year Review releases the 2012–2019 window as a single dataset — here's what your system reported, year by year. Values shown are the highest detection per analyte per year, compared to the federal MCL.

ContaminantWorst detectionEPA limitYears (2012–2019)
MERCURY
worst: 2012
0.011 mg/L
5.5×
0.002 mg/L
'12'14'15
ARSENIC
worst: 2017
0.0384 mg/L
3.8×
2.9× the national p90
0.01 mg/L
'12'13'14'15'16'17'18'19
DBCP
worst: 2016
0.00026 mg/L
1.3×
near national p90
0.0002 mg/L
'12'13'14'15'16'17
EDB
worst: 2016
0.00006 mg/L
1.2×
0.00005 mg/L
'16'18'19
SELENIUM
worst: 2018
0.05 mg/L
1.0×
0.05 mg/L
'13'14'15'16'17'18
HAA5
worst: 2017
0.059 mg/L
98%
0.06 mg/L
'12'13'14'15'16'17'18'19
TTHM
worst: 2012
0.0769 mg/L
96%
0.08 mg/L
'12'13'14'15'16'17'18'19
GROSS BETA
worst: 2018
2.4 mrem/yr
within
4 mrem/yr
'18
NITRATE
worst: 2015
5.9 mg/L
within
10 mg/L
'12'13'14'15'16'17'18'19
PCE
worst: 2016
0.0028 mg/L
within
0.005 mg/L
'12'13'14'15'16'17'18'19
NITRATE NITRITE
worst: 2017
4.4 mg/L
within
10 mg/L
'16'17'18'19
ANTIMONY
worst: 2015
0.0021 mg/L
within
near national p90
0.006 mg/L
'12'13'14'15'16
FLUORIDE
worst: 2014
0.98 mg/L
within
4 mg/L
'12'13'14'15'16'17'18'19
DICHLOROETHYLENE 11
worst: 2019
0.0014 mg/L
within
below national p90
0.007 mg/L
'16'17'18'19
NITRITE
worst: 2015
0.17 mg/L
within
1 mg/L
'15'17'18
TCE
worst: 2019
0.00068 mg/L
within
0.005 mg/L
'18'19
DICHLOROPROPANE 12
worst: 2018
0.00066 mg/L
within
below national p90
0.005 mg/L
'12'13'14'15'16'17'18'19
CHROMIUM
worst: 2016
0.012 mg/L
within
above national p90
0.1 mg/L
'12'13'14'15'16
BARIUM
worst: 2017
0.12 mg/L
within
near national p90
2 mg/L
'12'13'14'15'16'17'18'19
CYANIDE
worst: 2018
0.01 mg/L
within
below national p90
0.2 mg/L
'18
CADMIUM
worst: 2014
0.000162 mg/L
within
below national p90
0.005 mg/L
'12'14'15
THALLIUM
worst: 2014
0.000026 mg/L
within
0.002 mg/L
'14
CIS DICHLOROETHYLENE 12
worst: 2012
0.00089 mg/L
within
below national p90
0.07 mg/L
'12'18'19
BERYLLIUM
worst: 2014
0.000037 mg/L
within
below national p90
0.004 mg/L
'14'15
URANIUM
worst: 2016
0.021 ug/L
within
near national p90
30 ug/L
'12'13'14'15'16'17'18'19
COPPER
worst: 2012
0.00291 mg/L
below national p90
'12'13'14'15'16'17'18'19
LEAD
worst: 2012
0.000492 mg/L
'12'13'14'15'16'17'18'19
DBAA
worst: 2012
0.0017 mg/L
'12'13'14'15'16'17'18'19
DCAA
worst: 2012
0.0098 mg/L
'12'13'14'15'16'17'18'19
MCAA
worst: 2014
0.0054 mg/L
'14'17'18'19
TCAA
worst: 2012
0.0049 mg/L
'12'13'14'15'16'17'18'19
BROMODICHLOROMETHANE
worst: 2012
0.0226 mg/L
'12'13'14'15'16'17'18'19
BROMOFORM
worst: 2012
0.0241 mg/L
'12'13'14'15'16'17'18'19
CHLOROFORM
worst: 2012
0.0277 mg/L
'12'13'14'15'16'17'18'19
DIBROMOCHLOROMETHANE
worst: 2012
0.0351 mg/L
'12'13'14'15'16'17'18'19
PWSID CA1510031 · Source: EPA Six-Year Review 4 (2012–2019). Values are the highest detection in each calendar year; non-detect years are omitted. Year tags above show every year with a detection.

VOCs & pesticides

ContaminantMeasuredStatus
1,2,3-TCP0.0401094696969697 UG/LAverageSource waterAt or above the limit
AtrazineA widely used agricultural herbicide that reaches water through runoff.Not detected UG/LHighest single sampleSource waterNone detected
BenzeneNot detected UG/LHighest single sampleSource waterNone detected
Benzo(a)pyreneNot detected UG/LHighest single sampleSource waterNone detected
ChloroethaneA volatile organic compound used in some industrial processes.Not detected UG/LHighest single sampleSource waterNone detected
ChloromethaneNot detected UG/LHighest single sampleSource waterNone detected
DichlorodifluoromethaneNot detected UG/LHighest single sampleSource waterNone detected
DichloromethaneNot detected UG/LHighest single sampleSource waterNone detected
EthylbenzeneNot detected UG/LHighest single sampleSource waterNone detected
SimazineNot detected UG/LHighest single sampleSource waterNone detected
TolueneNot detected UG/LHighest single sampleSource waterNone detected
XylenesA group of industrial solvents found in gasoline and paint.Not detected UG/LHighest single sampleSource waterNone detected

Physical & aggregate

ContaminantMeasuredStatus
OdorA measure of detectable smell in the water.2.7413793103448274 TONAverageSource waterApproaching the limit
Total Dissolved SolidsTotal dissolved solids — the combined content of all dissolved minerals and salts.190.47619047619048 MG/LAverageSource waterWithin the limit
Specific ConductanceA measure of how well water conducts electricity, which tracks dissolved mineral content.287.14285714285717 UMHO/CMAverageSource waterWithin the limit
TurbidityA measure of cloudiness from suspended particles in the water.0.2619047619047619 NTUAverageSource waterWithin the limit
ColorA measure of visible tint in the water.Not detected UNITSHighest single sampleSource waterNone detected
AlkalinityA measure of the water's capacity to neutralize acids.60.095238095238095 MG/LAverageSource waterDetected — no federal limit
HardnessA measure of dissolved calcium and magnesium minerals.76.84285714285714 MG/LAverageSource waterDetected — no federal limit
pHA measure of how acidic or basic the water is.7.87054054054054 PHAverageSource waterDetected — no federal limit
TemperatureThe measured temperature of the water sample.23.7 CAverageSource waterDetected — no federal limit

Radionuclides

ContaminantMeasuredStatus
Gross AlphaGross alpha particle activity — a combined measure of alpha-emitting radioactive substances.5.068333333333333 PCI/LAverageSource waterWithin the limit
Combined RadiumCombined radium-226 and radium-228 — naturally occurring radioactive elements.0.1524074074074074 PCI/LAverageSource waterWithin the limit

Metals

ContaminantMeasuredStatus
IronA naturally occurring metal common in groundwater.28.12 UG/LAverageSource waterWithin the limit
Chromium, HexavalentHexavalent chromium ('chromium-6') — the more toxic form of chromium.0.7808205128205128 UG/LAverageSource waterWithin the limit
NickelA metal from natural deposits and industrial discharge.2.75 UG/LAverageSource waterWithin the limit
ManganeseA naturally occurring metal from soil and rock.0.6550387596899225 UG/LAverageSource waterWithin the limit
ZincA naturally occurring metal that can also enter water from corroding pipes.7.729081632653061 UG/LAverageSource waterWithin the limit
AluminumA common element sometimes used as a treatment coagulant.Not detected UG/LHighest single sampleSource waterNone detected
BoronA naturally occurring element from rock and soil.139.33333333333334 UG/LAverageSource waterDetected — no federal limit
CalciumA naturally occurring mineral that contributes to water hardness.15.484444444444444 MG/LAverageSource waterDetected — no federal limit
MagnesiumA naturally occurring mineral that contributes to water hardness.2.262916666666667 MG/LAverageSource waterDetected — no federal limit
PotassiumA naturally occurring mineral from rock and soil.1.5291666666666668 MG/LAverageSource waterDetected — no federal limit
SodiumA naturally occurring salt component.27.708333333333332 MG/LAverageSource waterDetected — no federal limit
Strontium277.3809523809524 UG/LAverageSource waterDetected — no federal limit
Vanadium9.019648093841642 UG/LAverageSource waterDetected — no federal limit

Inorganic chemicals

ContaminantMeasuredStatus
SulfateA naturally occurring mineral from rock and soil.19.09090909090909 MG/LAverageEntry pointWithin the limit
ChlorideA naturally occurring salt compound.13.923255813953489 MG/LAverageSource waterWithin the limit

Disinfection byproducts

ContaminantMeasuredStatus
PerchlorateA chemical used in rocket fuel and fireworks that can also form during disinfection.Not detected UG/LHighest single sampleSource waterNone detected

Other

ContaminantMeasuredStatus
Carbon TetrachlorideNot detected UG/LHighest single sampleSource waterNone detected
ChlorobenzeneNot detected UG/LHighest single sampleSource waterNone detected
DehaNot detected UG/LHighest single sampleSource waterNone detected
DehpNot detected UG/LHighest single sampleSource waterNone detected
Dichloroethane 12Not detected UG/LHighest single sampleSource waterNone detected
MbaaNot detected UG/LHighest single sampleDistributionNone detected
O DichlorobenzeneNot detected UG/LHighest single sampleSource waterNone detected
P DichlorobenzeneNot detected UG/LHighest single sampleSource waterNone detected
StyreneNot detected UG/LHighest single sampleSource waterNone detected
Trans Dichloroethylene 12Not detected UG/LHighest single sampleSource waterNone detected
Trichlorobenzene 124Not detected UG/LHighest single sampleSource waterNone detected
Trichloroethane 111Not detected UG/LHighest single sampleSource waterNone detected
Trichloroethane 112Not detected UG/LHighest single sampleSource waterNone detected
Vinyl ChlorideNot detected UG/LHighest single sampleSource waterNone detected

PFAS ("forever chemicals")

ContaminantMeasuredStatus
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid, a chlorinated PFAS compound.Not detected NG/LHighest single sampleEntry pointNone detected
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)ADONA, a newer-generation PFAS replacement compound.Not detected NG/LHighest single sampleSource waterNone detected
4:2 Fluorotelomer sulfonic acid (4:2 FTS)4:2 fluorotelomer sulfonic acid, a PFAS-related compound.Not detected NG/LHighest single sampleEntry pointNone detected
6:2 Fluorotelomer sulfonic acid (6:2 FTS)6:2 fluorotelomer sulfonic acid, a PFAS-related compound.Not detected NG/LHighest single sampleSource waterNone detected
8:2 Fluorotelomer sulfonic acid (8:2 FTS)8:2 fluorotelomer sulfonic acid, a PFAS-related compound.Not detected NG/LHighest single sampleEntry pointNone detected
9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (9Cl-PF3ONS)9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid, a chlorinated PFAS compound.Not detected NG/LHighest single sampleEntry pointNone detected
Hexafluoropropylene oxide dimer acidHFPO-DA ('GenX chemicals'), a newer-generation PFAS replacement compound.Not detected NG/LHighest single sampleSource waterNone detected
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)N-ethyl perfluorooctanesulfonamidoacetic acid, a PFAS-related compound.Not detected NG/LHighest single sampleSource waterNone detected
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)N-methyl perfluorooctanesulfonamidoacetic acid, a PFAS-related compound.Not detected NG/LHighest single sampleSource waterNone detected
Perfluoro-3-methoxypropanoic acid (PFMPA)Perfluoro-3-methoxypropanoic acid, a PFAS-related compound.Not detected NG/LHighest single sampleEntry pointNone detected
Perfluoro-4-methoxybutanoic acid (PFMBA)Perfluoro-4-methoxybutanoic acid, a PFAS-related compound.Not detected NG/LHighest single sampleSource waterNone detected
Perfluoro(2-ethoxyethane)sulfonic acid (PFEESA)Perfluoro(2-ethoxyethane)sulfonic acid, a PFAS-related compound.Not detected NG/LHighest single sampleEntry pointNone detected
Perfluorodecanoic acid (PFDA)Perfluorodecanoic acid, a longer-chain PFAS 'forever chemical.'Not detected NG/LHighest single sampleEntry pointNone detected
Perfluorododecanoic acid (PFDoA)Perfluorododecanoic acid, a longer-chain PFAS 'forever chemical.'Not detected NG/LHighest single sampleEntry pointNone detected
Perfluoroheptanoic acidPerfluoroheptanoic acid, a PFAS 'forever chemical.'Not detected NG/LHighest single sampleSource waterNone detected
Perfluorotetradecanoic acid (PFTeDA)Perfluorotetradecanoic acid, a longer-chain PFAS 'forever chemical.'Not detected NG/LHighest single sampleSource waterNone detected
Perfluorotridecanoic acid (PFTrDA)Perfluorotridecanoic acid, a longer-chain PFAS 'forever chemical.'Not detected NG/LHighest single sampleSource waterNone detected
Perfluoroundecanoic acid (PFUnA)Perfluoroundecanoic acid, a longer-chain PFAS 'forever chemical.'Not detected NG/LHighest single sampleEntry pointNone detected
Perfluoroheptanesulfonic acid (PFHpS)Perfluoroheptanesulfonic acid, a PFAS 'forever chemical.'1.0484848484848486 NG/LAverageSource waterDetected — no federal limit
Perfluorohexanoic acidPerfluorohexanoic acid, a shorter-chain PFAS 'forever chemical.'1.105699481865285 NG/LAverageSource waterDetected — no federal limit
Perfluoropentanesulfonic acid (PFPeS)Perfluoropentanesulfonic acid, a PFAS 'forever chemical.'1.4363636363636363 NG/LAverageSource waterDetected — no federal limit
Perfluoropentanoic acidPerfluoropentanoic acid, a shorter-chain PFAS 'forever chemical.'1.0727272727272728 NG/LAverageSource waterDetected — no federal limit
PFBAPerfluorobutanoic acid, a shorter-chain PFAS 'forever chemical.'1.1545454545454545 NG/LAverageSource waterDetected — no federal limit
Source: Bakersfield, City of, CA's 2025 Consumer Confidence Report — the annual drinking-water report every U.S. utility is required to publish. The numbers on this page are the utility's own. A water-quality report covers an entire service area, not a single address.

People also ask about Bakersfield, City of, CA's water

+Is Bakersfield, City of, CA tap water safe to drink in 2025?

The 2025 Consumer Confidence Report for the Bakersfield, City of, CA water utility lists 2 contaminants at or above the federal limit: 1,2,3-TCP and PFOS. Whether that means the water is "unsafe" depends on which contaminant, how long the exposure, and individual health factors. The table on this page shows the measured value, the federal threshold, and the regulated statistic used for compliance.

+What contaminants are in Bakersfield, City of, CA tap water?

113 contaminants were measured in Bakersfield, City of, CA's 2025 Consumer Confidence Report, spanning other, pfas ("forever chemicals"), and metals. 65 have an enforceable federal limit; the rest are detected but unregulated. Every measured value, in the utility's own units, is on this page.

+Which contaminants exceed federal limits in Bakersfield, City of, CA tap water?

2 contaminants in Bakersfield, City of, CA's 2025 report sit at or above the federal limit: 1,2,3-TCP (8.0× the limit); PFOS (1.9× the limit). The EPA enforces these limits against the regulated reporting statistic — typically a running annual average or 90th percentile — not a one-off sample spike.

+What is the worst contaminant in Bakersfield, City of, CA tap water?

The contaminant with the highest measured value relative to its federal limit in the 2025 report is 1,2,3-TCP, at 8.0× the federal threshold. It belongs to the vocs & pesticides family of contaminants.

+Are any contaminants in Bakersfield, City of, CA tap water approaching the federal limit?

One contaminant is between 80% and 100% of the federal limit in this report: Odor. Approaching means measured but not in violation — a margin that can close quickly if conditions change.

+Where does the data on this page come from?

Every value is transcribed from Bakersfield, City of, CA's 2025 Consumer Confidence Report — the annual drinking-water report every U.S. public water utility is required by federal law to publish. The original source document is archived and viewable on this site. A water-quality report covers an entire service area, not a single address.

+How often is Bakersfield, City of, CA's water quality data updated?

Each U.S. public water utility publishes one Consumer Confidence Report per year, covering the prior calendar year's measurements. This page reflects the 2025 report; a new report will replace it once the utility publishes its next annual update.

More water systems in CA